18 | Maintenance and repair

10.3 Vacation and Extended Shutdown

If the water heater is to remain idle for an extended period of 
time, the power and water to the appliance should be isolated 
to conserve energy and prevent the build up of dangerous 
hydrogen gas.

The electric water heater and piping should be drained if they 
might be subjected to freezing temperatures. After a long 
shutdown period, the water heater’s operation and controls 
should be checked by qualified service person.
Make certain the electric water heater is completely filled again 
before operating.

10.4 Flushing the water heater 

10.4.1 Draining the water heater

▶ Isolate the electrical supply at the main switchboard via the 

circuit breaker switch or isolating switch, and then remove 
the fuse.

▶ Isolate the cold water supply to the appliance.
▶ Gently raise the lever on the PTR valve to relieve the 

pressure in the water heater until flow stops.

▶ Disconnect the cold water connection to the appliance and 

attach drain hose.

▶ Operate the lever on the PTR valve again allowing air into 

the water heater. 

▶ The water heater will drain through the hose.

10.4.2 Flushing the water heater

▶ Complete the draining operation(

section 10.4.1) then 

disconnect the hot water outlet connection and attach a 
water supply hose to the water heater.

▶ Turn on the water supply and allow flow until the water from 

the inlet becomes clear.

▶  After the water from the inlet becomes clear, remove the 

hose and reconnect the hot and cold water connections.

10.4.3 Filling the water heater

▶ Open all hotwater taps in the house.
▶ Open the cold water isolating valve to the water heater.
▶ Close each tap as water flows freely from it.
▶ Check all piping for leaks.
▶ Reconnect power to the water heater.

Fig. 7

DANGER: 

Before manually operating the relief valve, 
make certain no one will be exposed to the 
hot water released by the valve. The water 
drained from the tank may be hot enough to 
present a scald hazard and should be 
directed to a suitable drain to prevent injury 
or damage.

WARNING: 

Draining and flushing the water heater must 
only be carried out by an authorised service 
person. 

A regular 5 years service plan by an 
authorised person would include: draining 
flushing, and refilling the water heater

CAUTION: 

Turn off the power supply to the water 
heater before draining water.

If you intend on being away from your house 
for only a few days, we suggest you leave the 
water heater switched on. 

Large volumes of water will drain from the 
cold water inlet.
▶ Ensure proper drainage of water.

Содержание Tronic 1000 T

Страница 1: ...ad the installation instructions before installing the appliance Please read the operating instructions before commissioning the appliance Please observe the safety instructions in the operating instructions The installation location must meet the manufacture s requirements Installation must only be carried out by an authorised person ...

Страница 2: ... Temperature mixing device not supplied with the appliance 13 5 4 PTR Valve connection 13 6 Electrical connection 14 7 Seismic strapping 15 8 Commissioning 15 8 1 Before commissioning 15 8 2 Switching the appliance on off 15 9 Service 16 9 1 General inspections 16 9 2 Save a service call 16 9 2 1 Lack of hot water 16 9 2 2 High hot water usage 16 9 2 3 High electricity bills 16 9 2 4 Continuous di...

Страница 3: ...verunlessthepowersupplyhas been effectively disconnected by an authorised person Do not operate this water heater with terminal box cover removed or loose This water heater is not intended to be operated or adjusted by young children or infirm persons Young childrenmustbesupervisedtoensuretheydonotinterfere with the water heater This water heater is intended to be installed as a fixed appliance an...

Страница 4: ... can result in severe injuries to young children Feel water temperature before bathing or showering Scaldscanoccurwhenchildrenareexposed directly to hot water when they are placed into a bath that is too hot WARNING Additional temperature control or limiting devices such as tempering valves may be required to be fitted to this water heater to meet regulatory requirements WARNING If the hot water h...

Страница 5: ...lve during the heating cycle Continuous leakage of water from the valve may indicate a problem with the water heater If the valve does not discharge water when the easing gear is operated or does not seal again a service call should be made without delay The PTR valve is not serviceable CAUTION The activation of the thermal cut out indicates a possibly dangerous situation Donotresetthethermalcut o...

Страница 6: ...to ensure hot water is available Thetankisamainspressuretank Itisdesignedtosupplywater at mains pressure above 350kPa If the maximum cold water pressure exceeds 680kPa a pressure limiting valve must be fitted The sacrificial anode in your water heater located at the top of the water heater will slowly erode to protect the cylinder Water heater life expectancy is dependent on a number of factors in...

Страница 7: ... by an authorised person When an ECV is required to be fitted a small amount of water maybedischargedduringtheheatingcycleratherthanthePTR valve IMPORTANT Where fitted gently operate the easing lever on the ECV every six months and replace at intervals not exceeding 5 years or more frequently in areas with poor quality water Please refer to the Water Quality Statement on Page 19 and the Warranty D...

Страница 8: ...ter connections RP 20mm Relief valve setting kPa 850 Expansion control valve ECV kPa 700 Maximum supply pressure with ECV kPa 500 Maximum supply pressure without ECV kPa 680 Electrical characteristics Power supply voltage V 240 Thermostat temperature Temperature range C 50 C to 70 C Factory set C 65 C General Data Weight empty unpacked kg 38 49 62 83 94 114 Outer case material Painted zinc coated ...

Страница 9: ...ontrol valve ECV kPa 700 Maximum supply pressure with ECV kPa 500 Maximum supply pressure without ECV kPa 680 Electrical characteristics Power supply voltage V 240 Thermostat temperature Temperature range C 50 C to 70 C Factory set C 65 C General Data Weight empty unpacked kg 48 57 83 Outer case material Painted zinc coated steel Inner tank material Enamel lined steel cylinder Insulation CFC free ...

Страница 10: ...de Connections Fig 3 Dimensions in mm Vertical installation Appliance A B C D E EWS 80 1060 470 40 854 74 EWS 125 1511 470 40 1305 74 EWS 160 1512 540 50 1295 74 EWS 250 1407 648 96 1161 74 EWS 260 1407 648 96 1161 74 EWS 315 1710 648 96 1464 74 EWS 400 1731 730 116 1464 74 Table 4 ...

Страница 11: ... and transported in its original packaging in an upright position Appliance A B C D EWS 135 1467 470 40 74 EWS 180 1408 540 40 74 Table 5 DANGER The activation of thermal cut out indicates a potentially dangerous situation 6720821421 04 1V DANGER Do not reset the thermal cut out until it has been serviced by an authorised person WARNING Do not operate this electric storage water heater without a t...

Страница 12: ...edonthe cold water line of the water heater It is recommended that a union be fitted to the cold and hot water connections to allow easy disconnection of the appliance WARNING Electric water heaters are heavy and bulky Australian States and Territories have a Principal Occupational Health and Safety OH S Act which contains requirements relating to the handling of large bulky or awkward items Perso...

Страница 13: ... and the tank Please observe local codes for the correct installation of relief valve drains The PTR valve thread is RP 15mm BSP Ensure the valve probe is straight and undamaged Carefully apply Teflon tape to the valve ensuring that the tape does not extend past the end of the thread The drainpipe must be fitted to the relief valve to carry discharge safely away from the water heater see AS NZS350...

Страница 14: ...be checked and operated AT LEAST ONCE EVERY SIX MONTHS If water does not discharge freely when the lever is operated the valve should be checked by an authorised agent WARNING The relief valve and relief valve drain pipe must not be sealed or blocked Small amounts of water may leak from the relief valve during heating cycles WARNING Relief valves should be replaced at intervals not exceeding 5year...

Страница 15: ...0L B Storage water heaters to be restrained with 25x1 galvanized steel straps tensioned when fixed in place Straps to be fixed to wall framing with 1 No 8 coach screw with 30x2 thick washer or 2 No 20x2 5 thick washers Screws to penetrate timber framing a minimum of 50 C 50x50 vertical blocking full height of water heater fixed to wall framing with 1 No 100x3 75 nail at 600 maximum centres 1 Stora...

Страница 16: ...ed Hot Water or Water Heater There may also be another isolating switch near the water heater 9 2 2 High hot water usage Generally this is related to increased showering times Investigate the installation of water saving devices such as flow reduction valves or water saving shower roses 9 2 3 High electricity bills Generally linked to high hot water usage However leaking valves and pipework may al...

Страница 17: ...ppliances even when new make some sound when in operation If the hissing or singing sound level increasesexcessively theelectricheatingelementmayrequire cleaning Contact a qualified installer or service agent 10 2 Pressure and temperature relief valve PTR Valve At least every 6 months Lift and release the lever handle on the PTR valve to make certain the valve operates freely Allow several litres ...

Страница 18: ...ater Complete the draining operation section 10 4 1 then disconnect the hot water outlet connection and attach a water supply hose to the water heater Turnonthewatersupplyandallowflowuntilthewaterfrom the inlet becomes clear After the water from the inlet becomes clear remove the hose and reconnect the hot and cold water connections 10 4 3 Filling the water heater Open all hotwater taps in the hou...

Страница 19: ...r in long periods of no use When this is likely to occur the installer should instruct the householder on how to dissipate the gas safely This process is explained on the previous page under Safety The change of anode must be done by a plumber or authorised service person Corrosive Water Waterdeemedtobecorrosivecanattackpartscausingthemto fail When the water supply Saturation Index check with your...

Страница 20: ...ding labour costs where indicated It does not cover any costs incurred by the end user in normal or scheduled maintenance of the Product or subjecttoany lawtothecontrary any damagetoproperty personal injury direct or indirect loss consequential losses or other expenses arising from breach of this warranty Any end user concerned with this exclusion shouldconsiderthe ImportantNote MandatoryAustralia...

Страница 21: ...der this voluntary warranty meets the requirementssetoutbelowinthe HowtoMakeaWarranty Claim section Warranty Exclusions This warranty will not apply to a defect or fault to the extent to which it arises due to storage handling or installation of the Product otherwise than in accordance with instructions provided for the Product by Bosch or without reasonable care includinginstallationofaProductwhi...

Страница 22: ... any potential product safety concerns within and outside the warranty period Bosch is well aware of its product liability and product safety obligations and responsibilities It is our aim to ensure appropriate product safety standards are met in order to avoid injury loss and damage caused by defects in any Product Privacy Bosch is required to seek personal information from an end user who seeks ...

Страница 23: ...6 720 821 421 2017 04 Tronic 1000 T 23 Notes ...

Страница 24: ......

Отзывы: