After installation
15
TR4000 | TR4000R – 6 720 876 021 (2019/06)
2.10 Controlling temperature
The supply temperature (probably lower in winter) and
pressure fluctuations can influence the temperature of the
water leaving the tap.
•
Turn the valve slowly in the closed direction for higher
temperatures (
F1
).
•
Add cold water for lower temperatures (
F2
).
Electrical connection (Fig. 5)
2.11 TR4000 5 ET, TR4000 6 ET, TR4000 6 EB,
TR4000 8 ET and TR4000 8 EB
(fixed electrical connection)
•
Connect the appliance on the terminal strip in accordance
with the connection schematic.
•
Put on the housing cover and push it onto the rear wall of
the appliance so that the upper and lower latches engage.
2.12 TR4000 4 ET and TR4000R 4 ET
Replacing the Power Supply Cord:
•
The power supply cord must be replaced by our customer
service only in order to avoid a hazard. The mains plug must
be pulled before replacing.
2.13 For all appliances
•
Vent the continuous-flow heater: Fully open the warm water
tap and flush out the appliance for about 1 minute (
G
), until
bubbles no longer emerge.
3
After installation
3.1
TR4000 5 ET, TR4000 6 ET, TR4000 6 EB,
TR4000 8 ET and TR4000 8 EB
(fixed electrical connection)
Switch on the fuses.
3.2
TR4000 4 ET and TR4000R 4 ET
•
Insert the plug into the mains socket.
First start-up (Fig. 6)
3.3
Initial rinsing
•
Open the warm water tap and allow water to flow for at least
1 minute (flow-rate at least 2 litres per minute). Only then
(for safety reasons) will the appliance begin to heat.
Info
: The appliance will not heat if the dispensed water flow is
interrupted prematurely. Open the warm water tap again and
allow water to flow for at least 1 minute.
Tip:
Should the appliance not start because of a reduced flow-
rate, remove the perlator, aerator or similar before starting and
repeating the process.
Important
: If the continuous-flow heater does not have
sufficient water flow due to low water line pressure in your
domestic plumbing system:
•
Switch off the circuit-breakers/fuses or remove the mains
plug.
•
Remove the flow-rate limiter (
H1
–
H4
).
3.4
Controlling temperature
The supply temperature (probably lower in winter) and
pressure fluctuations can influence the temperature of the
water leaving the tap (see Fig. 4, left: pressurised [closed],
right: unpressurised [open]).
•
Turn the valve slowly in the closed direction for higher
temperatures (
F1
).
•
Add cold water for lower temperatures (
F2
).
•
Hand over the installation and operating instructions
to the user and explain how the appliance operates.
1 min
G
Содержание TR4000
Страница 99: ...99 TR4000 TR4000R 6 720 876 021 2019 06 2 ...
Страница 100: ...TR4000 TR4000R 6 720 876 021 2019 06 100 3 ...
Страница 101: ...101 TR4000 TR4000R 6 720 876 021 2019 06 4 5 1 TR4000 4 ET TR4000R 4 ET 2 TR4000 5 ET 6 ET 8 ET 6 EB 8 EB ...
Страница 102: ...TR4000 TR4000R 6 720 876 021 2019 06 102 6 ...
Страница 103: ...103 TR4000 TR4000R 6 720 876 021 2019 06 ...
Страница 104: ...Bosch Thermotechnik GmbH Junkersstrasse 20 24 D 73249 Wernau www bosch thermotechnology com 6720876021 ...