Basic settings
en
35
Basic setting
Display text
Selection
Description
TimeLight
S01
1
S00 - S01
Switch TimeLight on or off.
While the programme is running,
status information is projected onto
the floor below the appliance door
relating to timer programming, the
programme or the time remaining. If
the base panel is pulled forwards or
if the appliance is installed at eye
level with the cabinet front fitted
flush, the display is not visible.
Level "S00" switches TimeLight off.
Tone volume
b02
1
b00 - b03
Adjustment of tone volume.
Level "b00" switches the signal tone
off.
Wi-Fi
Cn0
1
Cn0 - Cn1
Switch the wireless network connec-
tion on or off.
Level "Cn0" switches the wireless
network connection off.
Remote Start
rc1
1
rc0 - rc2
Activate or deactivate
.
The following settings are possible:
¡
With the setting "rc0", the func-
tion is permanently deactivated.
¡
With the setting "rc1", the func-
tion can be selected via the
button.
¡
With the setting "rc2", the func-
tion is permanently activated.
Factory setting
rE
Start with
YES
Confirm with
Restore changed settings to the fact-
ory settings.
The settings for initial start-up must
be configured.
1
Factory setting (may vary according to model)
Changing basic settings
1.
Open the appliance door.
2.
Press .
3.
To open the basic settings, press
for 3 seconds.
a
The display shows Hxx.
a
The display shows
.
4.
Press
repeatedly until
the display shows the required set-
ting.
5.
Press
repeatedly until the dis-
play shows the right value.
You can change several settings.
6.
To save the settings, press
for 3 seconds.
Содержание SMV6ZCX01G