TroubleshootingNL
Malfunction
Cause
Troubleshooting
Appliance door does not open at
the end of the programme.
Appliance door rubs
against appliance or
kitchen furniture
▶
Install and align the device correctly
with the aid of the installation
instructions.
Appliance door opens too
far at the end of the
programme.
Door is not set correctly.
▶
Set the appliance door correctly with
the aid of the installation instructions.
The door gap must be at
least 70 mm to 100 mm.
Wrong screws were
used to adjust the
door gap.
▶
Use size 4X30 screws to
adjust the door gap.
The screws are supplied as
standard.
Using screws that are too
long may disable the
automatic door opening
function.
Error code / error indication / signal
Malfunction
E:20-60 lights up alternately.
Cause
Troubleshooting
The appliance has
detected a calcified
heating element.
1.
Descale the appliance.
2.
Use the appliance with the
water softener.
1
E:30-00 lights up alternately.
Aquastop system is
activated.
1.
Close the tap.
2.
Contact the "service
Page 61.
E:31-00 lights up alternately.
Aquastop system is
activated.
1.
Close the tap.
2.
Contact the "service
Page 61.
E:32-00 lights up alternately
or water supply indicator
lights up.
Water supply hose is
kinked.
▶
Route the water inlet hose
without kinks.
Tap is closed.
Tap is clogged or calcified.
▶
Turn on the tap.
▶
Turn on the tap.
The amount of water flowing
in when the tap is open is at
least 10 l/min.
1
Depending on the device version
45