2
Avoiding General Hazards
Do not use the dishwasher until it is completely installed. When opening
the door on an uninstalled dishwasher, carefully open the door while
supporting the rear of the unit. Failure to follow this warning can cause the
dishwasher to tip over and result in serious injury.
Before installing the supplied counter top mounting brackets, decide which
method will be used to secure the dishwasher into its opening. Once these
mounting brackets are installed on the dishwasher, removing them is dif
-
ficult and will damage the mounting brackets and the dishwasher.
In some conditions, hydrogen gas can form in a hot water system that
has not been used for weeks. Hydrogen gas is explosive. Before filling a
dishwasher from a system that has been off for weeks, run the water from
a nearby faucet in a well ventilated area until there is no sound or evidence
of gas.
Removing any cover or pulling the dishwasher from the cabinet can
expose hot water connections, electrical power and sharp edges or points.
Handle with care.
Avoiding Electrical Shock/Fire Hazards
Do not work on an energized circuit. Doing so could result in serious
injury or death. Only qualified electricians should perform electrical work.
Do not attempt any work on the dishwasher electric supply circuit until
you are certain the circuit is de-energized.
Make sure electrical work is properly installed. There should be no loose
electrical connections. Ensure all electrical connections are properly
made.
The customer has the responsibility of ensuring that the dishwasher
electrical installation is in compliance with all national and local electrical
codes and ordinances. The dishwasher is designed for an electrical
supply of 120V, 60 Hz, AC, connected to a dishwasher-dedicated, properly
grounded electrical circuit with a fuse or breaker rated for 15 amps.
Electrical supply conductors shall be a minimum #14 AWG copper only
wire rated at 75°C (167°F) or higher.
WARNING
Содержание SHEM63W5 N Series
Страница 1: ...Installation Instructions Notice d installation Instrucciones de instalación 9001244446 Rev A 9609 ...
Страница 2: ......
Страница 8: ...Materials supplied Slotted Toe Panel Slotted Toe Panel Screws Ø 4x16mm G H 6 ...
Страница 29: ......
Страница 30: ......
Страница 36: ...Matériel fourni Panneau de plinthe à fentes Vis pour le panneau de plinthe à fentes de 4 x 16 mm G H 6 ...
Страница 57: ......
Страница 58: ......
Страница 64: ...Materiales suministrados Panel de pie con ranuras Tornillos del panel de pie con ranuras Ø 4 x 16 mm G H 6 ...
Страница 87: ......
Страница 88: ......