Troubleshooting
en
37
Fault
Cause
Troubleshooting
Display for water supply
lights up
9.
Check the water connection for
leaks.
10.
Restore the power supply.
11.
Switch the appliance on.
Wastewater hose is blocked
or kinked.
1.
Reposition the wastewater hose
without kinks.
2.
Remove residues.
Siphon connection is still
sealed.
▶
Check the connection to the siphon
and open if necessary.
Cover of the wastewater
pump is loose.
▶
Secure the cover of the "Wastewa-
ter pump "
into position.
Display "Check water sup-
ply" flashes
A technical fault is present.
1.
Press .
2.
Unplug the appliance or switch off
the fuse.
3.
Wait at least 2 minutes.
4.
Insert the mains plug of the appli-
ance in a socket or switch on the
fuse.
5.
Switch the appliance on.
6.
If the problem occurs again:
‒
Press .
‒
Turn off the water tap.
‒
Pull out the mains plug.
‒
ror code.
Displays flash
Appliance door is not closed
properly.
▶
Close the appliance door.
‒
Arrange the tableware so
that no parts project beyond
the basket and prevent the
appliance door from closing
properly.
Washing results
Fault
Cause
Troubleshooting
Tableware is not dry.
No rinse aid used or dosage
set too low.
1.
2.
Set the amount of rinse aid to be
dispensed.