background image

The ATEX certificate and the product
label carry the ATEX group and
category marking:       II 2 G D

Where: 

signifies compliance with ATEX

II 

signifies suitability for use in 
surface industries

signifies suitability for use in 
Zone1

signifies suitability for use in the 
presence of gases

LBC 3437/00, LBC 3438/00 | 

Installation Manual

EN

| 3

5.0 Gland Fitting Instructions

signifies suitability for use in the 
presence of dust

The product label also carries the
following mark:

This signifies unit compliance to the
relevant European directives, in this case
94/9/EC, along with the number of the
notified body issuing the EC type
examination certificate.

• Fit sealing washer to gland.
•  Secure gland into the speaker.
•  Ensure that item 2 (outer seal) is in its 

relaxed state by unscrewing item 4 
until there is no compression on the seal.

• Pass the cable through the gland to the 

desired length. Then tighten item 4 
into item 1 by hand until heavy 
resistance is felt then using a spanner 
rotate item 4 one turn.

• This completes the termination.

Figure 1

Bosch Security Systems | July 2003

LBC3437/LBC3438_instal.manual  05-09-2003  10:18  Page 3

Отзывы: