RF1100
| Installation Instructions | 2.0 Setup
4
Bosch Security Systems, Inc | 01/07 | 4998138680-01
2.0 Setup
1.
Carefully open the service door (Item 3 in Figure 4)
and insert the two AA batteries (supplied),
observing the correct polarity.
2.
Select a mounting location (refer to Section 1.0
Installation Considerations on page 3).
3.
Temporarily mount the unit so you can remove it
as needed.
2.1 Sensitivity
Setting
1.
If the front housing is attached, carefully open the
service door (Item 4 in Figure 5).
2.
Enable the LEDs for test purposes by sliding the
LED ENABLE switch (Item 5 in Figure 5) in the
direction the arrow points (above the switch). An
orange flag protrudes from the side of the RF1100.
Figure 4: RF1100 Front Layout
8
9
3
5
7
6
1
EVENT
4
2
1 - Service door tamper
switch
2 - AA batteries
3 - Service door
4 - SW4 Test Mode
pads
5 - SW3 sensitivity DIP
switches
6 - Alarm LED
7 - Event LED
8 - LED enable switch
(off position)
9 - Housing screw
Figure 5: Sensitivity Switch
EVENT
3
2
4
5
1
1 - SENS2
2 - Test Mode pads
3 - SENS1
4 - Service door
5 - LED enable switch
(shown in the OFF
position)
3.
Determine the sensitivity setting for your
application from Table 1.
Table 1: RF1100 Sensitivity Settings
Sensitivity SENS1 SENS2 Approximate
Range
Maximum
OFF
OFF
25 ft (7.6 m)
Medium
ON
OFF
15 ft (4.6 m)
Low
OFF
ON
10 ft (3 m)
Lowest
ON
ON
5 ft (1.5 m)
4.
Use a small flat head screwdriver to move the
sensitivity switches. Use the settings determined in
Step 3.
5.
Turn on any sources of noise such as machinery,
office, or audio equipment in the area.
6.
Observe the green event LED (Item 7 in Figure 4)
for approximately 1 min. If the green LED flashes,
relocate the unit or reduce the sensitivity by
adjusting the sensitivity switch.
7.
Repeat Steps 3 through 6 until you achieve the best
sensitivity level.
8.