Select this function if the visualization interface should be loaded from the
control to the IndraControl VCH 08.1 and should be executed.
If "Upload from Data Source" is selected, not the locally filed visualization
software is started, but the application of the control to be visualized is
loaded and started. If the load process fails, an error message will be dis‐
played and the locally filed application will be started.
Disable key state transmission to
control
The UDP telegrams are not transmitted to the control.
Enable key state transmission to
control
●
Control IP:
IP address of the control to which the UDP telegrams are to be sent.
The following data are sent to the control (control IP) via UDP telegram:
–
Key codes for IndraControl VCH 08.1
–
Data of additional elements, e.g. handwheel, override or key switch.
Fig.9-8:
Info Page
The Info Page tab provides information on software versions and memory lo‐
cations for the Bosch Rexroth Service.
After having edited the values and confirmation with the "ENTER" key, the data
is written back into the connection module or into the local file. Then the Indra‐
Control VCH 08.1 is started newly, so that the network driver is initialised with
the modified data.
9.2.7
Basic Settings
All basic settings of the IndraControl VCH 08.1 are made via the "Rexroth Set‐
tings". If an operating system update is performed, the Rexroth Settings start
automatically.
The Rexroth Settings of the IndraControl VCH 08.1 are read out from the In‐
draControl VAC 30.2/3.1 connection module, see also
.
If the IndraControl VAC 30.2/31.1 connection module is put into
operation the first time, all values are set to the standard values
(Obtain an IP-address via DHCP, disable UDP).
DOK-SUPPL*-VCH*08.1***-PR02-EN-P
Rexroth IndraControl VCH 08.1 Hand-held Terminal
Bosch Rexroth AG
97/117
Software
Содержание Rexroth VCH 08.1
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 12: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 10 117 ...
Страница 28: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 26 117 ...
Страница 60: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 58 117 ...
Страница 92: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 90 117 ...
Страница 114: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 112 117 ...
Страница 118: ...Bosch Rexroth AG DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal 116 117 ...
Страница 119: ...Notes DOK SUPPL VCH 08 1 PR02 EN P Rexroth IndraControl VCH 08 1 Hand held Terminal Bosch Rexroth AG 117 117 ...