3 608 878 300
Tightening Technology |
Bosch Rexroth AG 617
System 350
| 3 608 878 300/2019-03
7.7.2.4
Motor release interruption at the LTS350D/LTE350D
At the XDN3 interface, see figure
, the motor release can be interrupted via a potential-free opening
contact.
PIN 1 and 2 are equipped with a jumper at the factory to ensure that the motor is ready for operation.
Fig. 7–41:
Interface XDN3
7.7.2.5
Inserting and connecting the modules
Proceed as follows to insert and connect the modules:
•
Insert components in accordance with chapter
•
Insert the available interface modules in accordance with chapter
•
Insert the socket for the hand-held nutrunner connection cable in the correct position in the plug on
the nutrunner handle and tighten the union nut connection by hand
•
Insert the plug for the nutrunner connection cable in socket XDS1 (Figure
) on the LTU350/1
servo amplifier and/or LTS350D/LTE350D and tighten the union nut connection by hand
•
Establish the other required connections in accordance with
•
Switch on the power supply for the BT or on/off switch on the SB
•
Connect the PC for programming in accordance with chapter
Connecting the PC for programming
(not necessary if commissioning a complete package).
7.7.3
Configuring the tightening channel
The standard configuration of the ErgoSpin tightening channel is automatically configured during
commissioning. No configuration changes are required for basic commissioning. The configuration can
also be implemented manually at
System
Tightening channel configuration (
see
), if you are using deviating versions, additional components, or working in
offline mode.
Channel configuration created offline with an ErgoSpin VarioLine (ESV) or pistol grip nutrunner
(ESM)
For reasons of securing the tightening system, the following restriction applies to tightening channel
configurations created offline which contain an ErgoSpin of type VarioLine (ESV) or of type pistol grip
nutrunner (ESM): the tightening controller does not accept this tightening channel configurations. The
tightening channel configuration can be sent to the tightening controller (
Data
Send …
or
Data
Send to …
), it is, however, not accepted.
Table 7–39:
Positions of the PIN plug in the LTS350D/LTE350D
PIN plug in
position:
Explanation
1
Motor-breaker Out
2
Motor-breaker In
General information on sending files can be found at
Содержание Rexroth Tightening System 350
Страница 4: ...4 641 Bosch Rexroth AG Schraubtechnik System 350 3 608 878 300 2019 03 ...
Страница 120: ...120 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 194: ...194 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...
Страница 638: ...638 641 Bosch Rexroth AG Tightening Technology 3 608 878 300 System 350 3 608 878 300 2019 03 ...