182
Bosch Rexroth AG
| Tightening Technology
3 608 878 300
System 350
| 3 608 878 300/2019-03
5.6.8
Cancelation of a tightening process by removing the En enable signal
(1)
Input,
(2)
Output
5.6.9
Acknowledgement of a class 3 system error via the PLC interface
(1)
Input,
(2)
Output
A class 3 system error occurs in the tightening controller, i. e. the tightening controller is no longer ready-
to-operate (Rdy = "low"). The system error is acknowledged when the
ResF
signal changes from "low"
to "high", i.e. NF = “high”, and the controller is ready again (
Rdy
= "high").
5.6.10
PLC behavior with a class 1 system error
A class1 system error occurs in the tightening controller, i.e. the tightening controller is no longer ready
for operation (
Rdy
= "low"). As an error of this error class cannot be acknowledged via the PLC interface,
the tightening controller does not react to the
ResF
signal changing from "low" to "high" and the
timeout
of 1 s elapses without the system error being acknowledged.
A class 1 error can only be acknowledged by switching the system off and on or by resetting the
controller.