7.9.4 Pressure Drop / Overshoot Compensation
Pressure drop / overshoot compensation function helps to compensate the in-
coming pressure drop or overshoot by previously changing pressure command
with digital from customer PLC.
Code
Name
Setting range
Default
Min.
Attri.
F2.16
...
F2.25
X1...EX5 input
0...19, 22: See
ter list of group F2" on page 66
20: Pressure drop compensation
trigger
21: Pressure overshoot compensa-
tion trigger
0
-
Stop
F4.03 Pump function configuration
word
0...63
Bit0: Pump power limit
Bit1: Pump thermal protection
Bit2: Switch master to slave
Bit3: Two points / double pump
Bit4: Pressure drop / overshoot
compensation
Bit5: Activating myCro
0
-
Stop
F4.45 Pressure boost for drop
compensation
0.0…1,000.0 bar
0.0
0.1
Run
F4.46 Pressure reduce for over-
shoot compensation
-1,000.0…0.0 bar
0.0
0.1
Run
Tab. 7-17: Parameter list of pressure drop / overshoot compensation
Set control bit: bit4 of F4.03 to active this function, and configure the corre-
sponding digital input Xn to 15 or 16 for compensation command (from custom-
er PLC). For a high input (=1), the pressure command will be modified with the
value from F4.45 / F4.46. If the digital input is 0, the effective pressure com-
mand value will be reset to original.
The switch time of digital input should be optimized according to application.
Bosch Rexroth AG
Block Diagram of Main Functions
FcP 5020
40/83
DOK-RCON03-FCP5020****-QU04-EN-P