65
Interface description
6
en
Functional description
Setting the length of the moving average filter for actual position
values
Send
SET;POSE_FILTER;(filter length)
Description of
transmission
parameters
z.B. SET;POSE_FILTER;10
Transmission type
Filter length = number of actual position values which are used as
filters
Receive
UINT32
Description of response
value
SET;POSE_FILTER;OK
Response type
Status
Persistence
ENUM(OK,ERROR)
6.5.3
LED modes
Functional description
Setting the LED mode. There is a description of the various modes in
a separate section. For the modes QUALITY and QUALITY_PEAK to
work correctly, it is necessary to set the necessary threshold values
with the command SET;LED_QUALITY_THRES!
Send
SET;LED_MODE;STATUS
Description of
transmission
parameters
LED mode
Transmission type
ENUM(OFF, STATUS, IO, GRAPH_XYZ, QUALITY, QUALITY_PEAK,
SENSOR)
Receive
SET;LED_MODE;OK
Description of response
value
Status
Response type
ENUM(OK,ERROR)
Persistence
Not persistent