Electric Drives
and Controls
3−41
Bosch Rexroth AG
RhoMotion
1070072367 / 04
Structure of the rho4.0
3.5.5
Remote control with ROPS4 and virtual PHG
In a permanent network, the ROPS4 running on an external PC can be
coupled to the rho4.0.
With the virtual PHG, the rho4.0 can be operated via TCP/IP.
Settings on the rho4.0
L
At the PHG under MODE 9.1.1 enter the coupling:
Type (0=Ser/1=Win):
Win. chan
Port number
:
6010
Interface
:
0
L
At the PHG under MODE 9.1.17 enter Virt_PHG:
Type (0=Ser/1=Win):
Win. chan
Port number
:
6100
Settings on the remote PC
L
In the file ‘hosts’ assign all rho4.0 that are to be remote-controlled with
alias names and IP address.
L
Edit the alias name of the rho4.0 which are to be remote controlled in the
file C:\Bosch\rho4\Office\VirtPHG.ini in section [VirtPHG] at the item
“ServerAlias” (e.g. rho40_1).
At the item “ServerPortNo” the same port number which was edited be-
fore at the PHG under MODE 9.1.17 must be inserted here (e.g. 6100)
.
The file ‘hosts’ is to be found in the Windows directory, e.g.
C:\Winnt\system32\drivers\etc
Connecting ROPS4
L
Start ROPS4 to connect to the desired rho4.0.
L
In the setup of ROPS4-Online under [Options][Setup...] enter the rho4.0
with alias name that is to be remote-controlled:
Connection
:
TCP/IP
IP-Address/Alias name
:
rho40_1
Port number
:
6010
In this case, the rho4.0 with the alias name rho40_1 would be remote-
controlled.
Содержание Rexroth Rho 4.0
Страница 12: ...XII Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 Contents Notes ...
Страница 22: ...2 2 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 System overview Notes ...
Страница 78: ...4 14 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 PCLrho4 0 Notes ...
Страница 168: ...A 4 Electric Drives and Controls Bosch Rexroth AG RhoMotion 1070072367 04 Appendix Notes ...