RE 90300-B/2021-01-19, Bosch Rexroth AG
Installation |
Axial piston units
35
/64
3.
Push the axial piston unit to the cardan shaft and place the cardan shaft on the
drive shaft of the axial piston unit.
4.
Bring the axial piston unit to the installation position and fasten it. Details of the
required tools and tightening torque for the mounting bolts can be obtained from
the system manufacturer.
7.4.7 Completion of assembly
1.
Remove any installed transport screws.
CAUTION!
Operation with protective plugs!
Operating the axial piston unit with protective plugs may result in injury or damage
to the axial piston unit.
▶ Before commissioning, remove all protective plugs and replace them with suitable,
pressure-resistant, metal threaded plugs or connect the appropriate lines.
2.
Remove the transport protection.
The axial piston unit is delivered with protective covers and protective plugs.
They are not pressure-resistant and have to be removed prior to connection.
Use a suitable tool for this to prevent damage to the sealing and functional
surfaces. If sealing or functional surfaces are damaged, contact your
Bosch Rexroth service partner or the service department of the manufacturer's
plant of the axial piston unit.
Ports intended for connecting lines come with protective plugs and/or threaded
plugs, which serve as transport protection. All ports required for the function
must be connected. Failure to do so could lead to malfunctions or damage.
If a port is not being used, plug it with a threaded plug since the protective plugs
are not pressure-resistant.
Setting screws are protected against unauthorized adjustment by tamper-proof
caps. Removal of the tamper-proof caps will void the warranty. If you need to
change the settings, please contact your local contact person; you can find their
contact information at
www.boschrexroth.com/addresses
3.
For versions with through drive, assemble the auxiliary pump according to the
pump manufacturer's manual. The protective cover on the through drive is not
pressure-resistant and should not be used during operation.