MPH-02, MPB-02, MPD-02
Handling, Diagnostic and Service Functions
10-87
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Activating a Command
In the drive controller a number of commands can be activated the
execution of which takes place automatically within the controller.
The following command parameters are available:
•
switching between operating mode and parameter mode:
•
S-0-0127, C0100 Communication phase 3 transition check
•
S-0-0128, C0200 Communication phase 4 transition check
•
P-0-4023, C0400 Communication phase 2 transition
•
S-0-0262, C07_x Load defaults procedure command
•
S-0-0099, C0500 Reset class 1 diagnostics
•
S-0-0148, C0600 Drive-controlled homing procedure command
•
P-0-0012, C0300 Command Set absolute measuring
Via the serial interface it is possible to start, interrupt and complete the
execution of a command. In addition, the status of the command
execution can be read.