10-80
Handling, Diagnostic and Service Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Error Messages in the Case of Serial Communication
The error codes defined in the SERCOS interface specification are used
for the different errors (see "Specification SERCOS interface", section
7.4.2.3 "Service channel error messages"). These codes are also used in
the case of incorrect access to control and system parameters.
Error code
Description
0x1001
no IDN
0x1009
invalid access to element 1
0x2001
no name
0x2002
name transmission too short
0x2003
name transmission too long
0x2004
name cannot be changed (read only)
0x2005
name is write-protected at this time
0x3002
attribute transmission too short
0x3003
attribute transmission too long
0x3004
attribute cannot be changed (read only)
0x3005
attribute is write-protected at this time
0x4001
no units
0x4002
unit transmission too short
0x4003
unit transmission too long
0x4004
unit cannot be changed (read only)
0x4005
unit is write-protected at this time
0x5001
no minimum input value
0x5002
minimum input value transmission too short
0x5003
minimum input value transmission too long
0x5004
minimum input value cannot be changed (read only)
0x5005
minimum input value is write-protected at this time
0x6001
no maximum input value
0x6002
maximum input value transmission too short
0x6003
maximum input value transmission too long
0x6004
maximum input value cannot be changed (read only)
0x6005
maximum input value is write-protected at this time
0x7002
operation data transmission too short
0x7003
operation data transmission too long
0x7004
operation data cannot be changed (read only)
0x7005
operation data is write-protected at this time (e.g. communication
phase)
0x7006
operation data is smaller than the minimum input value
0x7007
operation data is greater than the maximum input value
0x7008
invalid operation data
0x7009
operation data write protected by a password
0x700A
operation data is write protected, it is configured cyclically
0x700B
invalid indirect addressing (e.g., data container, list handling)
0x700C
operation data is write protected, due to other settings
(e.g., parameter, operation mode, drive enable, drive on etc.)
Fig. 10-40: Error specification according to SERCOS