10-4
Handling, Diagnostic and Service Functions
MPH-02, MPB-02, MPD-02
DOK-INDRV*-MP*-02VRS**-FK01-EN-P
Loading parameter values is required in the following cases:
•
initial commissioning of the motor (loading basic parameter values and
motor-specific parameter values)
•
serial commissioning of machine axes at series machines (loading the
values saved after initial commissioning)
•
reestablishing a defined original status (repeated loading of the values
saved after initial commissioning)
•
replacing the controller for servicing (loading the current parameter
values saved before servicing)
Possibilities of loading parameter values to the controller:
•
motor encoder data memory
→
loading the parameter values by
command or via the control panel during initial motor commissioning
•
MMC
→
loading the parameter values by command
•
"DriveTop" commissioning tool
→
loading the parameter values from
external data carrier
•
control
master
→
loading the parameter values from master-side data
carrier
By means of checksum comparison, the control master can determine
whether the values of the application-specific parameter values currently
active in the drive correspond to the values saved on the master side.
•
S-0-0017, IDN list of all operation data
•
S-0-0192, IDN-list of backup operation data
•
S-0-0262, C07_x Load defaults procedure command
•
S-0-0263, C2300 Load working memory procedure command
•
S-0-0264, C2200 Backup working memory procedure command
•
S-0-0269, Parameter buffer mode
•
S-0-0270, Selected IDN list of operation data to backup
•
S-0-0293, C2400 Selectively backup working memory procedure
command
•
S-0-0326, Parameter checksum
•
S-0-0327, IDN list of checksum parameter
•
P-0-0013, IDN list of modified parameters
•
P-0-4023, C0400 Communication phase 2 transition
•
P-0-4065, Non-volatile memory active
•
P-0-4090, Index for C07 Load defaults procedure
•
P-0-4091, C2500 Copy IDN from optional memory to internal
memory
•
P-0-4092, C2600 Copy IDN from internal memory to optional
memory
Loading Parameter Values
Checksum of Parameter Values
Pertinent Parameters