5.4.2
KCU02 data sheet
KCU data sheet - Currents, voltages, power
Description
Symbol
Unit
KCU02.2N-ET-ET*-025-NN-N-NN-NW
Listing in accordance with UL
standard
UL 508C
Listing in accordance with CSA
standard
C22.2 No. 14-10
UL files
E134201
Mass
m
kg
3.80
Degree of protection according to
IEC60529
IP20
Minimum distance on the top of
the device
1)
d
top
mm
80
Minimum distance on the bottom
of the device
2)
d
bot
mm
110
Horizontal spacing on the device
3)
d
hor
mm
0
Temperature increase with mini‐
mum distances d
bot
; d
top
; P
BD
ΔT
K
Less than 60
Cooling type
Forced
Volumetric capacity of forced cool‐
ing
V
m
3
/h
approx. 0.3
Power dissipation at continuous
current and continuous DC bus
power respectively
4)
P
Diss_cont
W
90
Insulation resistance at 500 V DC
R
is
Mohm
>50
Average sound pressure level (ac‐
curacy class 2) at P
DC_cont
5)
L
P
dB (A)
Less than 70
Control voltage data - input
Control voltage input
6)
U
N3
V
24 ± 20%
Rated power consumption control
voltage input at U
N3
7)
P
N3
W
675
Max. inrush current at 24 V supply
I
IN3_max
A
10.00
Pulse width of I
EIN3
t
EIN3Lade
ms
Less than 1000
Input capacitance
C
N3
mF
11.00
Maximum allowed voltage for
1 ms
U
N3_max
V
33.00
Control voltage data - output
Nominal voltage
V
out
V
42.0
Nominal power
P
out
W
588.0
Last modification: 2015-10-07
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
86/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components