1
Segment length (l
seg
)
2
Maximum allowed length in flexible cable track (l
max_schlepp
)
3
Example: With a segment length of 60 m, the maximum al‐
lowed length in the flexible cable track is approx. 32 m.
A
l
seg
= 75 m; l
max_schlepp
= 11.5 m
B
l
seg
= 48 m; l
max_schlepp
= 48 m
Fig. 7-12:
Maximum allowed cable length for routing in the flexible cable track
The length l
max_schlepp
taken from the figure is the length of the movable part of
the cable connection between two motors. The RKH0700 cable can be used
for the movable part of the flexible cable track connection so that it is replace‐
able and thereby easy to maintain.
Technical justification of the specified lengths: Only within the specified
lengths is it ensured that the properties of the Ethernet communication (at‐
tenuation, crosstalk) remain in the allowed range during the service life of the
cable.
Length of hybrid cable without communication
In preparation
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
Bosch Rexroth AG
207/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Notes on project planning
LSA Control S.L. www.lsa-control.com [email protected] (+34) 960 62 43 01