5.8
RKH hybrid cable
5.8.1
RKH hybrid cable incl. communication, technical data
Data sheet - bulk cable
Description
Symbol
Unit
REH0800
Brief description of cable
[5x2.5mm² + 5x0.34mm² + (2x2x0.34mm²)StC]C
RoHS
compliant with EU Directive 2002/95/EC
Recognized UL and CSA
1)
cURus
AWM Style
AWM20234
Diameter
D
mm
16.2 +/- 0.5
Power core cross section
mm
2
2.5
Cable jacket material
2)
PUR
Cable jacket color
RAL2003
Specific cable weight
m
kg/m
0.355
Temperature range for storage
°C
-30 ... +60
Ambient temperature at operation
(permanent installation)
°C
-30 ... +80
Ambient temperature at operation
(flexible installation)
°C
-20 ... +80
Operating temperature at conduc‐
tor (flexible/permanent)
°C
80
Leakage capacitance
C
Y_K_typ
Conductor resistance at 20°C (EN
60228; class 6)
R
20
ohm/km
8 (2.5 mm²)
Operational voltage at power
cores
V
850
Operational voltage at control
cores
V
100
Halogens
Halogen-free acc. to VDE 0472, Part 815
Oil resistance
EN 60811-2-1 and EN 50363-10-2
Flammability
UL 7 58, section 40, Cable Flame Test Section 1061 according to
UL 1581 and CSA C22.2 No. 210-05 Sec. 8.8.2 Test according to
EN 60332-1-2
Flexible cable tracks
Suitable for application in flexible
cable tracks
Yes
Bending cycles
5
Bending radius with flexible instal‐
lation
mm
10 x D
Last modification: 2013-04-15
Bosch Rexroth AG
DOK-INDRV*-KCU02+KSM02-PR03-EN-P
106/337
Rexroth IndraDrive Mi Drive Systems with KCU02 KSM02, KMS02/03, KMV03, KNK03
Technical data of the components