Switching off power supply via
firmware
The "parking axis" firmware command (C1600) causes the encoder power
supply to be switched off.
7.1.13
Length of motor cables and encoder cables at KMS
The allowed length of motor cables at connection X156 or X104 of KMS is
limited (see description of connection point
).
7.1.14
Operation with standard motors
KMS02 near motor servo drives without X104 connection (encoder
interface = "NNN") are provided for operating converter-proof standard
motors.
Guide value "Rise of voltage at output"
When selecting standard motors, make sure that they comply with
the occurring voltage load "rise of voltage at output" (see
).
Selecting standard motors
The table below shows the nominal powers P
nenn
of standard motors which
can be operated. The data are subject to the following conditions:
●
Motor design:
4-pole standard motor (2 pole pairs) with rated voltage 3 AC 400 V,
50 Hz at mains voltage U
LN
≥ 3 AC 400 V or
●
Operation at minimum switching frequency f
s
= f
s
(min.)
●
Rotary field at output with f
out
> f
out_still
●
Overload ratio K = P
DC_peak
/ P
DC_base
according to "UEL_P_e"
performance profile
Observe the performance data P
DC_peak
and P
DC_base
in the
"UEL_P_e" performance profile of the supply unit and the
performance data of the KCU drive connection box.
Selecting standard motors 3 AC 400 V - exemplary profiles
Description
Symbol
Unit
KMS02.1B-A018
Nominal power standard motor
3 AC 400 V; 50 Hz; t > 10 min;
K = 1.0; f
s
= 4 kHz
1)
P
Nenn
kW
≤ 2.2
Nominal power standard motor
3 AC 400 V; 50 Hz; t = 60 s;
T = 10 min; K = 1.1; f
s
= 4 kHz
2)
P
Nenn
kW
≤ 1.5
Nominal power standard motor
3 AC 400 V; 50 Hz; t = 60 s; T = 5
min; K = 1.5; f
s
= 4 kHz
3)
P
Nenn
kW
≤ 1.5
Nominal power standard motor
3 AC 400 V; 50 Hz; t = 2 s;
T = 20 s; K = 2.0; f
s
= 4 kHz
4)
P
Nenn
kW
≤ 1.5
Latest amendment: 2016-02-11*
1) 2) 3) 4)
See UEL_P_e profile definition
Tab. 7-7:
KMS - Selecting standard motors 3 AC 400 V - exemplary profiles
IndraDrive Mi Drive Systems with KCU02, KSM02,
KMS02/03, KMV03, KNK03, KLC03
243/407
Notes on project planning
R911335703_Edition 04 Bosch Rexroth AG
Содержание Rexroth IndraDrive Mi KCU02
Страница 272: ...258 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 290: ...276 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 312: ...298 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 378: ...364 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 382: ...368 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 408: ...394 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 Bosch Rexroth AG R911335703_Edition 04 ...
Страница 420: ...Notes 406 407 IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 ...
Страница 421: ...Notes IndraDrive Mi Drive Systems with KCU02 KSM02 KMS02 03 KMV03 KNK03 KLC03 407 407 ...