Module bus cable shield connection
Use shielded cables for the module bus in the following cases:
●
An individual module bus connection is > 0.5 m long.
●
All drive system module bus connections together are > 3 m long.
The HAS09.1-001 accessories contain parts for assembling shielded module
bus cables:
●
Heat shrink tubing (3 × 20 mm)
●
Self-adhesive copper tape (1 × 30 mm)
Use shielded cables of a conductor size ≥ 2 × 0.5 mm
2
.
Observe the data of connection point
.
Assembling cables:
1. Strip cable: A = 24 mm, B = 180 mm, C = 35 mm
Fig. 8-5:
Stripping the cable
2. Remove protective foil, then wrap self-adhesive copper tape around
shield braid.
Fig. 8-6:
Copper tape
3. Put 2 heat shrink tubings on cable and shrink them.
Fig. 8-7:
Heat shrink tubing
4. Fold back shield braid over cable jacket and strip wire ends.
Fig. 8-8:
Shield braid, wire ends
Bosch Rexroth AG
DOK-INDRV*-HCS01******-PR05-EN-P
256/341
Rexroth IndraDrive CsDrive Systems with HCS01
Cables, accessories, additional components
Содержание Rexroth IndraDrive CsDrive System with HCS01
Страница 1: ...Rexroth IndraDrive Cs Drive Systems with HCS01 Project Planning Manual R911322210 Edition 05 ...
Страница 30: ...Bosch Rexroth AG DOK INDRV HCS01 PR05 EN P 28 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...
Страница 250: ...Bosch Rexroth AG DOK INDRV HCS01 PR05 EN P 248 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...
Страница 314: ...Bosch Rexroth AG DOK INDRV HCS01 PR05 EN P 312 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...
Страница 318: ...Bosch Rexroth AG DOK INDRV HCS01 PR05 EN P 316 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...
Страница 332: ...Bosch Rexroth AG DOK INDRV HCS01 PR05 EN P 330 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...
Страница 342: ...Notes Bosch Rexroth AG DOK INDRV HCS01 PR05 EN P 340 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...
Страница 343: ...Notes DOK INDRV HCS01 PR05 EN P Bosch Rexroth AG 341 341 Rexroth IndraDrive CsDrive Systems with HCS01 ...