7.14
X49, optional safety technology Safe Torque Off
View
Connec‐
tion
Signal name
Function
1
SI_Ch2
Input for selection of channel 2
2
0V
Power supply of inputs/outputs
3
SI_Ch1
Input for selection of channel 1
4
+24V
Power supply of inputs/outputs
5
Dyn_Ch2
Dynamization output channel 2
6
Dyn_Ch1
Dynamization output channel 1
Spring terminal (connector)
Unit
Min.
Max.
Connection cable
Stranded wire
mm
2
1
1.5
AWG
16
16
Stripped length
mm
-
8
Tab. 7-13:
X49, optional safety technology Safe Torque Off
When the dynamization outputs do not work, check the power
supply connection. The polarity might possibly have been re‐
versed.
Technical data
chapter "Digital inputs (safety technology L options)" on page 117
chapter "Digital Outputs (Safety Technology L Options)" on page 120
7.15
X49.1, X49.2, optional safety technology Safe Torque Off
Assignment
X49.1: Axis 1
X49.2: Axis 2
Pin assignment
chapter 7.14 "X49, optional safety technology Safe Torque Off" on page 74
Bosch Rexroth AG
DOK-INDRV*-CXX02******-PR03-EN-P
74/143
IndraDrive Control Sections CSB02, CSE02, CSH02, CDB02
Optional connection points
Courtesy
of
CMA/Flodyne/Hydradyne
▪
Motion
Control
▪
Hydraulic
▪
Pneumatic
▪
Electrical
▪
Mechanical
▪
(800)
426-5480
▪
www.cmafh.com