6.12
X36, digital inputs/outputs, analog outputs
View
Connec‐
tion
Signal name
Connec‐
tion
Signal name
Function
1.1
OA_1
2.1
OA_2
Analog output
1.2
GND_A1
2.2
GND_A2
GND reference of analog output
1.3
GND_100
2.3
GND_100
GND reference
Connection for inner cable shield
1.4
I_17/O_3
2.4
I_20/O_6
Digital input/output
1.5
I_18/O_4
2.5
I_21/O_7
1.6
I_19/O_5
2.6
I_22/O_8
Spring terminal (con‐
nector)
Unit
min.
max.
Connection cable
Stranded wire
mm
2
0.2
1.5
AWG
24
16
Stripped length
mm
-
10
Tab. 6-14:
Function, pin assignment, properties
GND Reference
X33/1.2 is the GND reference of the digital inputs and outputs.
Shield connection
chapter 9.3 "Analog inputs/outputs: Shield connection" on page 130
Technical data
chapter 8.7.2 "Digital inputs" on page 115
chapter 8.7.3 "Digital Outputs" on page 119
chapter 8.10 "Analog Output" on page 125