Loss of UL/CSA conformity due to modifications at the device.
UL and CSA marking applies only to the device upon delivery. After
modifying the device, verify the UL and the CSA conformity.
9 Interfaces
1
2
3
4 5 6
7 8
Fig. 9-1: Interfaces of the built-in devices (for names, refer to the following table)
9.1 Overview
Name at the
housing
Connection type
Connector type, inte-
grated
Mating connector or ca-
ble (from outside)
①
XD1
24 V DC voltage supply
3-pin, MC1,5/3- G-3,5
THT
3-pin, FK-MCP 1,5/3-
ST-3,5
②
XF20
Gigabit Ethernet interface
RJ45 socket
RJ45 plug
③
XF21
Gigabit Ethernet interface
RJ45 socket
RJ45 plug
④
XBAT
Battery connection
Molex Micro-Fit 3 mm Molex 43645-0200
(or compatible)
⑤
XG10
CFAST slot
CFAST socket
CFAST card
⑥
XF30
USB 2.0 interface
USB socket,
4-pin, type A
USB plug,
4-pin, type A
⑦
XF31
USB 3.0 interface
USB socket,
9-pin, type A
USB plug,
9-pin, type A
⑧
PE
Functional earth connection
M5 screw
Tab. 9-1: Interfaces
Malfunctions due to insufficient shielding!
NOTICE
Use only shielded cables and metallic or conductive connector/coupling covers
with large-area shield support.
9.2 24 V DC voltage supply
The 24 V power supply is connected to the XD1 connection.
16/49
Interfaces
IndraControl VEP 30.6, VEP 40.6,
VEP 50.6 Embedded Terminals
Bosch Rexroth AG R911403058_Edition 01
Содержание rexroth IndraControl VEP 30.6
Страница 6: ...IV IndraControl VEP 30 6 VEP 40 6 VEP 50 6 Embedded Terminals Bosch Rexroth AG R911403058_Edition 01 ...
Страница 52: ...46 49 IndraControl VEP 30 6 VEP 40 6 VEP 50 6 Embedded Terminals Bosch Rexroth AG R911403058_Edition 01 ...
Страница 55: ...Notes IndraControl VEP 30 6 VEP 40 6 VEP 50 6 Embedded Terminals 49 49 ...