Technical Data of the PROFIBUS Master Interface
Communication interface
PROFIBUS DP, 12 Mbaud max.,
potential-free
Diagnostic interface
RS 232C, 9600 baud, non-isolated
Fig.7-26:
Technical data of the PROFIBUS Master interface
Status and Diagnostic Displays of the PROFIBUS Master
The status and diagnostic displays of the PROFIBUS Master module are visible
on the front panel of the IndraControl VEP **.4.
During the startup the PROFIBUS Master card performs a self-test. After the
initialization phase of this test (2-3 seconds), the two "ERR" and "STA" LEDs
turn dark. The yellow "RDY" LED lights after successful completion of the ini‐
tialization phase. If errors occur during the initialization phase, the "RDY" LED
flashes and the program processing is terminated. Further meanings of the
display during the initialization phase are listed in
of the PROFIBUS fieldbus module" on page 91
.
LED BUS (red) On
Bus error and missing bus connection
Flashing
Slave diagnostic is pending
Off
No error / bus ok
LED stat
(green)
On
Communication is running
Flashing
No configuration
On
Configuration OK
Fig.7-27:
Diagnostic display of the PROFIBUS fieldbus module
7.3
Fieldbus Interface X7E3 and X7E4
This interface is only available for IndraControl VEP **.4 devices
with PROFIBUS configuration.
Via these Ethernet-based fieldbus interfaces the device can be connected to
the bus devices.
RJ45, female connector, 8-pin
Type
Ethernet 10 Base T / 100 Base X
Cable length
Maximum 100 m
Cable type
Shielded, twisted pair
Transmission rate
10 or 100 MBit/s
Fig.7-28:
Ethernet network connection
DOK-SUPPL*-VEP*XX.4***-PR03-EN-P
Rexroth IndraControl VEP **.4 Embedded Terminal
Bosch Rexroth AG
91/139
Pin Assignments
Содержание Rexroth IndraControl VEP 30.4
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 8: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal VI 139 ...
Страница 26: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 24 139 ...
Страница 36: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 34 139 ...
Страница 78: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 76 139 ...
Страница 126: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 124 139 ...
Страница 134: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 132 139 ...
Страница 136: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 134 139 ...
Страница 140: ...Bosch Rexroth AG DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal 138 139 ...
Страница 141: ...Notes DOK SUPPL VEP XX 4 PR03 EN P Rexroth IndraControl VEP 4 Embedded Terminal Bosch Rexroth AG 139 139 ...