Comply with the following steps during the assembly of the shield connection:
1. Only remove the CDI cable jacket on the length required for the connec-
tion.
The CDI cable is sensitive to mechanical load in the area where the
jacket has been removed. Make sure that the CDI cable shielding is
not damaged when removing the cable jacket.
Fig. 10-12: CDI cable with RJ45 connector
Fig. 10-13: CDI cable with partially removed jacket
2. Remove the foil shield.
CDI cables are equipped with an additional foil shield. The foil shield
must not be used for connection to the shield clamp. The foil shield
is usually plastic-coated on one side for an improved stability. The
plastic-coat insulates the foil shield.
Fig. 10-14: Foil shield of the CDI cable