Connect only USB devices that meet the USB2.0 specification.
If any problems result when using USB3.0 devices, please contact
the Bosch Rexroth Service.
The cables of the connected USB devices have to comply with the
USB2.0 specifications.
If the total current of all USB ports exceeds 1 A, the power supply
unit switches off the operator display.
9.6 XSER and XVID interfaces
9.6.1 CDI interface
The CDI interface is assigned to the two RJ45 sockets XSER and XVID. The con-
nection between the control cabinet PC and the operator display is established
at these sockets via two ready-made cables available as accessory, see
5 "Spare parts, accessories and wear parts" on page 6
.
The CDI interface includes the data interface (XSER) as well as the image inter-
face (XVID).
9.6.2 XVID and XSER marking
The CDI interfaces are color-coded on the device:
CDI interface, data (XSER)
Violet
CDI interface, image (XVID)
Black
Tab. 9-4: Color-coding of the interface
Bosch Rexroth AG
Interfaces
DOK-SUPPL*-VDPXX.3MTBU-IT03-EN-P
15/37
Содержание Rexroth IndraControl VDP 15.3 Multi Touch
Страница 6: ...Bosch Rexroth AG IV DOK SUPPL VDPXX 3MTBU IT03 EN P ...
Страница 40: ...Bosch Rexroth AG 34 37 DOK SUPPL VDPXX 3MTBU IT03 EN P ...
Страница 43: ...Notes Bosch Rexroth AG ...