4-2
Bosch Rexroth AG | Electric Drives and Controls
Rexroth IndraControl VCP 11.2 | R911311481 / 03
Technical Data
4.3
Electrical Data
4.4
Interfaces
Contrast setting
Temperature compen-
sated
-
Half-life backlighting
30,000 h
30,000 h
Brightness in cd/m
2
90
320
Display area (H x W) in mm (Inch)
57.6 x 76.8 (2.268 x
3.024)
53.6 x 71.5 (2.11 x 2.815")
Display
VCP 11.2
VCP 11.2T
Electrical Data
VCP 11.2
VCP 11.2T
Supply Voltage
24 V DC (SELV in Accordance with DIN EN 61131)
Residual Ripple
10 % Maximum
Minimum Voltage
18 V
Maximum Voltage
30 V
Power Consumption (Typical at 24 V)
0.25 A
0.2 A
Power Consumption (Maximum)
0.35 A
0.3 A
Connected Load
6 W
4.8 W
Fuse
Semiconductor Fuse, Self-resetting
Protection Against Polarity Reversal
Integrated
Ethernet
X5 Ethernet
10/100 Base-T
Serial Interfaces
Variable Baud Rates and Data Formats
X6 SER1 RS485
In Accordance With DIN 66259-4
Transmission Length: 0 - 1200 m (up to 3937 feet),
Twisted Pair Wire, Shielded
Galvanically Isolated
X6 SER1 RS232 / X6 SER2 RS232
In Accordance With DIN 66259 T1, CCITT V.28
Transmission Length: 0 - 15 m (up to 49.212 feet), Con-
ductors Layered in Strands, Shielded X6 SER1: Galvan-
ically Isolated
X6 SER2: Galvanically Not Isolated