8
-4
Bosch Rexroth AG
| Electric Drives and Controls
Rexroth IndraControl VCP 05
|
R911310377
/
02
Maintenance and Installation
2. Fit the wires with wire end ferrules and connect the wires to the con-
nector.
Fig. 8-4:
Connecting the female connector strip
3. Plug the female connector strip onto connector X1.
Fig. 8-5:
Female connector strip is plugged on
4. Secure the female connector strip in place with a screw-type locking
to prevent it from slipping out.
8.7
Front Panel
Only use a damp cloth to remove any dirt from the front panel.
If shielded connecting cables are used in the supply voltage area, the
shield should be connected to pin 1.
A separate conductor must always be provided for the protective
grounding at the threaded bolt. The conductor must have a minimum
cross-section of 1.5 mm² (16 AWG) and must be kept as short as pos-
sible.