5.6.2
Mounting Cut-Out
To mount the control panel, proceed as follows:
1. Create a mounting cut-out with 6 holes, cross-section 4.5 mm according
to
fig. 5-11 "Mounting dimensions VAM 12.1" on page 41
"Mounting dimensions VAM 42.1" on page 42
2. Insert the control panel from the front into the cut-out. Then insert the
mounting bolts M4 into the drilled holes.
3. Fasten the control panel by screwing the nuts at the rear side of the
mounting bolts.
Damage to the mechanics due to incorrect
tightening torque.
NOTICE
The tightening torque for M4 nuts (1.4 Nm) must not be exceeded.
5.6.3
Mounting Dimensions VAM 12.1
Mounting cut-out
215 x 324
225
240
7.5
167.5
167.5
350
7.5
Hole for threaded bolts
Fig.5-11:
Mounting dimensions VAM 12.1
DOK-SUPPL*-VAM*XX.1***-PR02-EN-P
Rexroth IndraControl VAM 12.1/42.1 Machine Control Panels
Bosch Rexroth AG
41/93
Dimensions and Installation