14
Troubleshooting
Malfunctions and information on errors are
displayed in the tightening system, e.g. in the
BS350.
The NS LED indicates the Modbus status.
The MS LED indicates the interface module
status.
If you should not be able to remedy an
occurring defect, please contact one of the
addresses that you can find under
www.boschrexroth.com or in the address
directory in chapter “16 Service and sales”
on page 26.
Table 5 NS
LED display
Meaning
Red
Double IP address or blocking
error
Flashing red
Timeout reached for an active
process
Table 6 MS
LED display
Meaning
Red
Exception error, module in
“EXCEPTION” status, or
blocking error
Flashing red
Error (but not an exception error),
module continues running in
restricted mode