5
Press to switch between region and truck name. Press
CHG
to start to edit region or truck name,
Then press
FINSH
button to quit editing.
4.2
Setting the UNIT
UNIT: To choose the system unit, metric or imperial.
4.3
Authorization method
LOCK: A valid programing key or six characters password can be chosen to verify the access to the setup.
4.4
Setting the Time
TIME: Clock time is formatted as: Hour: Minute: Second
4.5
Setting the Date
Date: is formatted as Month: Day: Year
4.6
Use External Boom Switches
N: Use on controller boom buttons Y: Use external boom switches
4.7
Recirculation mode
REC: Choose from the following modes:
AUTO --- Recirculate will automatically come on when unit is paused.
MAN --- Operator must press button on screen to recirculate.
OFF --- No recirculation.
MODE: Standard or Air Gate.
4.8
User Option
USER: This option determines whether truck driver is allowed to change the material or not.
N/A --- operator is not allowed to change material.
MAT --- operator is allowed to change material.
4.9
Alarm Speed
ALM: This is the ground speed at which a waring will be displayed on the screen. The "Alarm Speed" is not
activated when the spread rate is zero or the controller is in the Pause mode.
4.10
Liquid level detection
DI: This option determines whether the truck will have liquid level detection or not
N/A --- Liquid level detection disabled.
L-D --- Liquid level detection enabled.
4.11
Setting Dither Frequency
Two options: 66 and 150 Hz
4.12
Setting Beeping and Language
: Enable/disable beeping as feedback to touch pad press.
EN: Default language is English and can switch to French.
4.13
Default Setting and Season Reset
RS: system parameters can be reset to factory defaults or season totals can be reset to zero.
SUM: reset season totals