Code
Meaning
090
Profibus initialization error
093
BT bus error
Fig.9-12:
Error codes of MTS-P0*.2
Interface Assignment
The following tables list the interface assignments of the MTS-P modules.
PIN
Signal designation
PIN
Signal designation
1
NC
2
Transmit Data (RS232)
3
Receive Data (RS232)
4
RS485+ or RxD+ (RS422)
5
RS485- or RxD- (RS422)
6
NC
7
GND
8
NC
9
TxD+ (RS422)
10
GND
11
TxD- (RS422)
12
+5V
13
Request To Send (modem)
14
Clear To Send (modem)
15
NC
Fig.9-13:
Pin assignment COM interface X16
PIN
Signal designation
PIN
Signal designation
1
Data Out +
2
Data In +
2
GND
4
NC
5
+5V
6
Data Out -
7
Data In -
8
NC
9
Detection of the assignment
Fig.9-14:
Pin assignment BT bus X15
PIN
Function
X1.1 - X1.4
Supply voltage V
CC
X1.5 - X1.20
Input (0....15)
X1.21 - X1.36
Output (0....15)
X1.37 - X1.40
GND
Fig.9-15:
Pin assignment I/O connector, 40-pin, X12
PIN
Signal designation
PIN
Signal designation
1
+5VDC
2
+5VDC
3
S0
4
S1
5
S2
6
S3
7
S4
8
S5
9
S6
10
S7
11
S8
12
S9
116/135 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth MTA 200 | Project Planning Manual
PLC Modules MTS-P01.2 and MTS-P02.2
Содержание Rexroth BTV 20.4A
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 12: ...10 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Страница 66: ...64 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Страница 134: ...132 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Страница 137: ...Notes Project Planning Manual Rexroth MTA 200 Electric Drives and Controls Bosch Rexroth AG 135 135 ...