8.7.8
NCM in the BTV20.4A
The NC multifunction card is always inserted in slot U5 of the BTV20.4A. If more
than one SERCOS ring is required, the slot bracket with the additional optical
fiber component is plugged in the U6 slot.
The following assignment applies:
SERCOS rings
U5 slot
U6 slot
1
+NCM0201
Blind plate
2
+NCM0202
+NCMZ003
3
+NCM0204
+NCMZ004
Fig.8-15:
Combination matrix
A maximum of 3 SERCOS rings can be used in the MTA 200!
8.8
Connecting Cables
8.8.1
General Information
The SERCOS interface card of the MTA 200 is connected to the drives via the
SERCOS fiber optics cables. The connection is designed as a ring, i.e. at least
two SERCOS fiber optics cables are used depending on the number of drives.
Depending on the loacation of use, two different cables are used:
●
For wiring within the control cabinet, a fiber optic cable with a diameter of
2.2 mm is used.
●
Outside of the control cabinet, a sheathed fiber optic cable with a diameter
of 6.0 mm is used to resist higher mechnical loads.
Fig.8-16:
Internal and external SERCOS fiber optic cable
8.8.2
Cable Specifications
Cable length:
Maximum 20 m
Bending radius:
Minimum 50 mm
Internal wire:
Ø 2.2 mm
External wire:
Ø 6.0 mm
100/135 Bosch Rexroth AG | Electric Drives
and Controls
Rexroth MTA 200 | Project Planning Manual
NC Multifunction Card NCM02
Содержание Rexroth BTV 20.4A
Страница 1: ...Electric Drives and Controls Pneumatics Service Linear Motion and Assembly Technologies Hydraulics ...
Страница 12: ...10 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Страница 66: ...64 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Страница 134: ...132 135 Bosch Rexroth AG Electric Drives and Controls Rexroth MTA 200 Project Planning Manual ...
Страница 137: ...Notes Project Planning Manual Rexroth MTA 200 Electric Drives and Controls Bosch Rexroth AG 135 135 ...