Troubleshooting | Automax 100 | Extension module TS-AC E2-M3-1X
85/94
Bosch Rexroth AG | 05.2021 | DOK-SUPPL*-TS-AC E2-M3-ITRS-EN-P
Troubleshooting
DANGER
Compromising of the training system, individual components or other assets. Risk
for safe operation of the training system!
Risk of injury or death for operator or third
Chapter „
“ as of page [
] in these operating instructions must
always be observed!
DANGER
Working in the area of live parts is life-threatening!
Danger to life due to electrical voltage!
Work on the electrical system may only be carried out by qualified electricians.
Electrician's tool (VDE tool) is absolutely necessary
Do not disconnect or connect connectors under voltage
CAUTION
Material damage due to improper handling!
Proper handling can lead to damage or device defect!
Disconnect the base module from the supply voltage before carrying out any extension
or conversion work
Make sure that the polarity of the connections is correct. Observe color coding!
Carry out extension and conversion work without mechanical force
NOTICE
Do not touch electrostatically sensitive components or connection points!
Property damage
Observe the ESD protection measures
Do not touch connection points
Troubleshooting measures
Fault
Cause of error
Measures
No function of extension module
No voltage supply
Check the basic module. For information on
troubleshooting, please refer to the operating instructions
of the respective module.
In case of extension, make sure that all safety laboratory
sockets are connected. See also chapter „
“ as of page [
Input voltage incorrectly connected
Check correct polarity of the supply voltage.
General error
Check the status LEDs at the components. Information on
status and diagnosis indicators can be found in chapter
„
“ as of page [