![Bosch Rexroth A6VM series 71 Скачать руководство пользователя страница 2](http://html.mh-extra.com/html/bosch/rexroth-a6vm-series-71/rexroth-a6vm-series-71_manual_43003002.webp)
Bosch Rexroth Corp.
, RE-A 91610/12.2015
2
A6VM series 71 | Axial piston variable motor
Type code
Type code
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
A6V
M
0
0
/
71
A
W
V
0
–
Axial piston unit
01 Bent-axis design, variable, nominal pressure 6500 psi (450 bar), maximum pressure 7250 psi (500 bar)
A6V
Operating mode
02 Motor
M
Size (NG)
03 Geometric displacement, see technical data on page 8
in cm
3
/rev
060
085
115
150
170
215
in in
3
/rev
3.66
5.19
7.02
9.15 10.37 13.12
Control device
060
085
115
150
170
215
04 Proportional control
hydraulic
positive control
Δp
St
= 145 psi (10 bar)
●
●
●
●
●
●
HP1
Δp
St
= 365 psi (25 bar)
●
●
●
●
●
●
HP2
negative control
Δp
St
= 145 psi (10 bar)
●
●
●
●
●
●
HP5
Δp
St
= 365 psi (25 bar)
●
●
●
●
●
●
HP6
Proportional control
electrical
positive control
U
= 12 V DC
●
●
●
●
●
●
EP1
U
= 24 V DC
●
●
●
●
●
●
EP2
negative control
U
= 12 V DC
●
●
●
●
●
●
EP5
U
= 24 V DC
●
●
●
●
●
●
EP6
Two-point control
hydraulic
negative control
‒
‒
‒
●
●
●
HZ5
●
●
●
‒
‒
‒
HZ7
Two-point control
electrical
negative control
U
= 12 V DC
‒
‒
‒
●
●
●
EZ5
U
= 24 V DC
‒
‒
‒
●
●
●
EZ6
U
= 12 V DC
●
●
●
‒
‒
‒
EZ7
U
= 24 V DC
●
●
●
‒
‒
‒
EZ8
Automatic control
high-pressure related,
Positive control
with minimum pressure
increase
Δp
≤ approx. 145 psi (10 bar)
●
●
●
●
●
●
HA1
with pressure increase
Δp
= 1450 psi (100 bar)
●
●
●
●
●
●
HA2
Automatic control
speed related, negative
control
p
St
/
p
HD
= 5/100
hydr. travel direction valve
●
●
●
●
●
●
DA0
electric travel direction
valve + electric
V
g max
circuit
U
= 12 V DC
●
●
●
●
●
●
DA1
U
= 24 V DC
●
●
●
●
●
●
DA2
Pressure control/override
060
085
115
150
170
215
05 Without pressure control/override
●
●
●
●
●
●
00
Pressure control fixed setting, only for HP5, HP6, EP5 and EP6
●
●
●
●
●
●
D1
Override
of controls
HA1 and HA2
hydraulic remote control, proportional
●
●
●
●
●
●
T3
electric, two-point
U
= 12 V DC
●
●
●
●
●
●
U1
U
= 24 V DC
●
●
●
●
●
●
U2
electric and travel
direction valve, electric
U
= 12 V DC
●
●
●
●
●
●
R1
U
= 24 V DC
●
●
●
●
●
●
R2
Connector for solenoids
1)
(see page 62)
06 Without connector (without solenoid, only for hydraulic control)
0
DEUTSCH - molded connector, 2-pin, without suppressor diode
P
●
= Available
○
= On request
‒
= Not available
1)
Connectors for other electric components can deviate.