36/56 Installation
Bosch Rexroth AG
, A2FM/A2FE/A2FMT Series 70, RE 91071-01-B/06.2018
A
B
T
1
T
2
Fig. 15: A2FMT port overview, lateral SAE working ports and SAE mounting flange
Table 15: Ports A2FM/A2FE/A2FMT series 70
Ports
1)
p
max
[bar]
2)
State
A2FMn/
A2FEn
A2FMM/
A2FEM
A2FMH/
A2FEH
A2FMT
A, B
Working port
350
450
500
420
O
T
1
Drain port
3
3
3
3
X
3)
T
2
Drain port
3
3
3
3
O
3)
S
1
Boost port
(only on version with pressure relief valve)
–
5
–
–
O
M
A
, M
B
A/B pressure measuring port
(only on version with pressure relief valve)
–
420
–
–
X
P
St
Pilot pressure port (only on version with pressure
relief valve and pressure sequencing stage)
–
30
–
–
O
1)
The measuring system and thread size can be found in the installation drawing.
2)
Momentary pressure peaks may occur depending on the application. Keep this in mind when selecting measuring devices and
fittings.
3)
Depending on the installation position, T
1
or T
2
must be connected (see chapter 7.3 “Installation position” on page 26).
O = Must be connected (comes plugged)
X = Plugged (in normal operation)
The following tightening torques apply:
• Fittings:
Observe the manufacturer’s specifications regarding the tightening torques of the
fittings used.
• Female threads in the axial piston unit:
The maximum permissible tightening torques
M
G max
are the max. values of the
female threads and should not be exceeded. For values, see Table 16.
• Threaded plugs:
For the metallic threaded plugs supplied with the axial piston unit, the required
tightening torques of threaded plugs
M
V
apply. For values, see Table 16.
• Mounting bolts:
For mounting bolts with metric ISO threads as defined in DIN 13 or threads defined
in ASME B1.1, we recommend checking the tightening torque on a case-by-case
basis in accordance with VDI 2230.
Tightening torques