![Bosch Rexroth 4WRLE 4 Series Скачать руководство пользователя страница 18](http://html.mh-extra.com/html/bosch/rexroth-4wrle-4-series/rexroth-4wrle-4-series_operating-instructions-manual_46463018.webp)
18/44
Safety instructions
Bosch Rexroth AG
, 4WRPEH6_3X, 4WRPEH10_3X, 4WRPE6_3X, 4WRPE10_3X, 4WRLE_4X; RE 29118-B/09.2021
2.7.7 Connection example/block diagram for IO-Link valves
For category 1, the supply voltage of valve pin 2 and 5 must be safely switched off.
In this example, this is realized by means of safe limit switches at doors in
connection with a safe IO-Link terminal.
The voltage can also be safely switched off via an IO-Link-Master for safe shut-off of
the B voltage according to 13849-1.
Fig. 1: Category 1 block diagram
Category 1
M
3~
IO-Link
terminal with
safe separation
of power supply
from bus
K3
K2
IO-Link
24 V
1A
Dangerous
movement
High-response valve with
OBEA-V5 electronics and
IO-Link Class B
other actuators
Determination of
position
Control a
Control b
a
b
P
T
A
B
1V3
1S3
OBEA-V5
IO-Link
interface
IOL-Master
Outputs
PLC
Inputs
K1
O1.1
I1.1
I1.2
ÜB1
ÜB2
B1
ÜB1
B2
ÜB2
24 V
Open
Closed
1V2
1Z2
1S1 1S2
1Z1
1V1
1M
1P