Malfunction
6-1
1070 080 058-101 (2001.04) GB
6
Malfunction
Although the design of the thyristor power units is quite rugged, malfunctions
may occur in a few exceptional cases, e.g. for the following reasons:
D
incorrect electrical connection or mains voltage surges,
D
insufficient cooling or overload on the thyristor power unit may trigger the
thermal detector,
D
current parameters set are higher than the maximum current permitted or
the monitoring values.
In case of failure, the green LED ”Ready”
⇑
on the front panel of the weld
timer unit goes out. Further information is provided by the diagnostics func-
tion, the error message display on the BOS-5000 operator interface, or a
message on the Bosch BT operator terminal.
DANGEROUS ELECTRICAL VOLTAGE
Danger of life in case of contact with live parts!
Disconnect the system from the mains supply before troubleshoot-
ing or replacing a fuse!
Thermal detector response
The thyristor power unit contains a thermostatic switch, which transmits a
message to the integrated weld timer if the temperature reaches or rises
above
80
°
C (
$
5
°
C)
If this happens, the weld timer blocks any further sequence.
The green LED ”Ready” on the front panel of the weld timer unit goes out and
the message ”Thyristor unit temperature” is output.
Possible causes
Corrective action
Dirt accumulation in heat sink
Clean out the heat sink
Excessive ambient temperature
Check for sufficient convection.
Checking external forced ventilation
may be required.
Capacity of thyristor power unit too low Compute duty cycle and check selec-
tion using load diagram (see section
”Notes on Rating”).
No or insufficient cooling water flow
Check cooling water inlet and/or tem-
perature.
Содержание PST 6000 Series
Страница 4: ......
Страница 28: ...Notes on Rating 3 2 1070 080 058 101 2001 04 GB Notes ...
Страница 30: ...Commissioning 4 2 1070 080 058 101 2001 04 GB Notes ...
Страница 34: ...Malfunction 6 2 1070 080 058 101 2001 04 GB Notes ...
Страница 36: ...Type overview 7 2 1070 080 058 101 2001 04 GB Notes ...
Страница 57: ...CE declaration of conformity 10 1 1070 080 058 101 2001 04 GB 10 CE declaration of conformity ...
Страница 58: ...CE declaration of conformity 10 2 1070 080 058 101 2001 04 GB Notes ...
Страница 62: ...Annex A 4 1070 080 058 101 2001 04 GB ...
Страница 63: ...A 1 1070 080 058 101 2001 04 GB 1070 080 058 101 2001 04 GB TI WS AT VWS Printed in Germany ...