Open Ceiling Installation
The Bosch LC2-PC60G6-12 must be suspended from the back of the can in both open
ceiling and ceiling tile applications, using either the 3 pendant mount tabs or the 3/8”
threaded rigging point. To prevent rattles, rotate the 4 mounting tabs towards the can,
then tighten the mounting tab screws.
Figure 4a:
Pendant Mount Suspension
Pendant Mount
Tabs (x3)
Figure 4b:
3/8” Threaded Rod Suspension
3/8” Nut
(Loctite Applied)
Threaded Rod
Rigging Plate with
Integrated Nut
(Loctite Applied)