background image

PR109B-PR110B

Installer Reference Guide

3

Bosch Security Systems     09/11    PR109B-PR110BIRG  FTR1.1

Installation

The reader should be installed onto a solid surface using 
suitable mounting fixtures.  Wiring should only be  
performed while the control panel is powered off. 

Step 1)  Using the 1:1 mounting template supplied, mark 

out the location of the 2 mounting holes and 
the cable exit hole before drilling out all points 
as necessary.   

Figure 3: Mounting Template (Not to Scale)

Step 2)  If the reader is to occupy an address on the 

LAN other than address 1, you will need set the 
required address before mounting.  Note each 
reader on the system must have a unique  
address.  See Table 2: for more information. 

Step 3)  Once the address has been set, terminate the 

required wires referring to the Connection Dia-
gram on page 6.  Unused wires should be insu-
lated to prevent short circuits.

Step 4)  If using the on board lock output to open the 

door, you must make sure to use a relay and  
protection diode as shown. 

Step 5)  Once the wiring is complete, mount the reader 

to the wall and fit the cover plate using the M3 x 
6mm hex screws.  

Reader Operation

LAN Readers can be configured to provide system area 
control, door access control or both depending on the 
installation requirements.  

As there is no LCD display on the readers, feedback is 
provided via the red, green and blue indicators and the 
reader sounder.  

The readers also include an egress input and lock output 
which can be used to control door access if required.

i

Note

  Using the on board lock output is not recommend-

ed when the reader is being used on an external 
wall of the building.  In this case it is recommended 
that you run the lock control wires directly to an 
output located on the main panel or output ex-
pander module located inside the building.

LED Indicators

The Red and Green indicators on the reader show area 
status while the Blue indicator shows door status.  The 
addition of the Blue indicator allows the system to 
display both area and door status at the same time if 
required.

LED Operation For Area Control

Led

Condition

Meaning

Red

On

Area All On

Flashing

Area Alarm

Green

On

Area is OFF

Flashing

Area not ready to turn on - 
zone(s) unsealed

Red & 

Green

Both On

Area armed in Part mode 
and all zones sealed. 

Red & 

Green

Red On 

and  Green 

Flashing

Area armed in Part mode 
with zones unsealed.

Red & 

Green

Alternate 

Flashing

Keypad initialising during 
power up or LAN scan.

Red & 

Green

Both Off

Home Area and Access 
Group not programmed or 
keypad not powered.

Table 3: Reader LED’s - Area Control

i

Note

  The LED indicators will only display the status of 

the programmed home area.  You cannot move 
between areas from this reader.  If you require mul-
tiple area status visibility you should use a display 
keypad like the CP700B.

92.0mm

48.0mm

84.0mm

6 x 4.0mm

(1/8”) holes

Tamper Switch

Do Not Create A Hole

In This Location

Connection Cable

Entry Point

PR109B & PR110B Mounting Template

Scale 1:1

Rev 1

PR109B & PR110B Mounting Template.ai

Содержание PR109B

Страница 1: ...PR109B and PR110B LAN Reader Module Security System Installer Reference Guide EN Security Systems ...

Страница 2: ...clude a rotary address switch for quick selection The following table shows the address setting for each reader as well as the number of keypad reader devices each panel can support Reader Compatibility Panels Supported Version Keypads Supported Solution 16i 2 19 Up to 8 Solution 16X 2 00 Up to 8 Solution 144 GRAPHIC 2 00 Up to 16 Solution GRAPHIC 2 00 Up to 16 Table 1 LAN Reader Compatibility LAN...

Страница 3: ...r The readers also include an egress input and lock output which can be used to control door access if required i Note Using the on board lock output is not recommend ed when the reader is being used on an external wall of the building In this case it is recommended that you run the lock control wires directly to an output located on the main panel or output ex pander module located inside the bui...

Страница 4: ...lowest level See the Devices Keypads Readers Commands menu in panel programming i Note Setting the reader volume to off will stop all audible warning signals at the reader Reader Alert Tones Event Alert Tone Emitted Fire Alarm If the system registers a fire alarm the reader will sound 3 short beeps fol lowed by a 1 5 second pause This will repeat until reset by the user or until the siren run time...

Страница 5: ...the associated access group or door assignment is triggered i Note The on board lock output will operate for a fixed time period of 5 seconds when triggered If a dif ferent time is required then you should use another output on the system to operate the door lock The lock output and LAN power supply are not de signed to operate and power the door lock directly You should always fit a relay and pro...

Страница 6: ...l programming if required Lock Output EGRESS INPUT N O BK RD WH BL YL GN MODULE LAN CONTROL PANEL A B TO DOOR LOCK 12V DF70 N O COM N C CM444 Relay Card RED BLACK WHITE BLUE YELLOW GREEN LAN LAN LAN A LAN B LOCK EGRESS Wiring Legend DOOR LOCK PROTECTION DIODE CM444B RELAY CARD Egress Input R D CM720B or CM723B Power Supply Battery backed up To Cont r o l P a n e l The egress input is low 0V to tri...

Страница 7: ...utput 500mA Egress Input Low to trigger Can be disabled via software control Dimensions 74mm W 23mm D 116mm H CM444B 46mm W 12 5mm D 12mm H Environment 30 to 55 C RH 5 to 85 at 30 C non condensing Fixing Method The PR109B and PR110B should be mounted on a sturdy vertical wall using fixtures appropriate for the wall construction type Warranty 3 years from date of manufacture return to base N12138 N...

Страница 8: ...Bosch Security Systems 25 Huntingwood Drive Huntingwood NSW 2148 Australia Phone 612 9672 1777 Facsimile 612 9672 1717 2011 Bosch Security Systems PR109B PR110BIRG Issue FTR1 1 ...

Отзывы: