figure 2.3: Rear panel

Mute

Mix

Wall Panel

PLE-2CS

Apparatus delivered
connected for 230V~

Line fuse
T1L250V for 230V
T1.6L250V for 115V

Rated input
power: 40VA

Zone 1 Out

Zone 2 Out

Line
Out

Music
Only

Chime

Ducking

0

100V

In

1(disc)

2(radio)

3(aux)

Insert

Out

Call

Trigger

Gnd

Telephone/Emergency Input

Gnd

PLE-10M2-EU

2 Channel Mixer
115/230V~, 50/60Hz
S/N

Design & Quality

The Netherlands

F01U.066.938

8900 192 21001

Chime

Flat

PT

T

Mic

Flat

Vo

x

Mic

Phantom

Off

Speec

h

Off

Line

Speec

h

Off

Line

Off

Mic

Line

Mic

Line

Phantom

Off

Mic

Line

Mic

Line

Phantom

Off

Output

1

2

4

5

11

3

6

7

8

10

9

29

28

27

24

18 19 20 21 22

13

16

23

25

26

14 15

17

12

Содержание Plena PLE-2MA120-US

Страница 1: ...Installation and User Instructions PLE 2MA120 US PLE 2MA240 US en Plena Mixer Amplifier ...

Страница 2: ...he unit should not be placed in a built in installation unless proper ventilation is provided or the manufacturer s instructions have been adhered to Maintain a minimum distance of 2 inch 50 mm around the front the rear and the sides of the unit for sufficient ventilation 10 Heat sources Do not install the unit near any heat sources such as radiators stoves or other apparatus that produce heat inc...

Страница 3: ...tructions for use Adjust only those controls that are covered by the instructions for use as an improper adjustment of other controls may result in damage and will often require extensive work by a qualified technician to restore the units to their normal operation If the unit has been dropped or the unit has been damaged When the unit exhibits a distinct change in performance this indicates a nee...

Страница 4: ...se harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment OFF and ON the user is encouraged to try to correct the interference by one or more of the following measures Reorient or reloca...

Страница 5: ...nnectors and indicators 9 2 4 1 Front panel 9 2 4 2 Plena PLE WP2Z3S wall panel 9 2 4 3 Rear panel 10 3 Installation 13 3 1 Unpack unit 13 3 2 Install unit in rack optional 13 3 3 Check settings connections 13 3 4 Connect unit to mains 13 4 Connections and settings 15 4 1 Connecting inputs 15 4 1 1 DC supply battery 15 4 1 2 Priority microphone input 1 16 4 1 3 Secondary microphone input 2 17 4 1 ...

Страница 6: ... Microphone line tone control 28 5 4 3 Music tone control 28 5 5 Output controls 29 5 5 1 Zone selection 29 5 5 2 Master volume control 29 6 Technical data 31 6 1 Electrical 31 6 1 1 Mains power supply 31 6 1 2 Battery power supply 31 6 1 3 Power consumption 31 6 1 4 Performance 31 6 1 5 RJ 45 input 2 x 31 6 1 6 Mic line input 6 x 31 6 1 7 Music inputs 3x 32 6 1 8 Emergency telephone 1 x 32 6 1 9 ...

Страница 7: ...alerts from least severe effect to most severe effect are Note Alert containing additional information Usually not observing a note alert does not result in damage to the equipment or personal injuries Caution The equipment can be damaged if the alert is not observed Warning Persons can be severely injured or the equipment can be seriously damaged if the alert is not observed Danger Not observing ...

Страница 8: ...e converted to non metric units using the following information table 1 1 Conversion of units of length 1 in 25 4 mm 1 mm 0 03937 in 1 in 2 54 cm 1 cm 0 3937 in 1 ft 0 3048 m 1 m 3 281 ft 1 mi 1 609 km 1 km 0 622 mi table 1 2 Conversion of units of mass 1 lb 0 4536 kg 1 kg 2 2046 lb table 1 3 Conversion of units of pressure 1 psi 68 95 hPa 1 hPa 0 0145 psi Note 1 hPa 1 mbar table 1 4 Conversion of...

Страница 9: ...has enhanced features such as ducking level control priority labelling and setting indicators All Microphone line inputs can be switched between microphone level and line level sensitivity The inputs are balanced but can also be used unbalanced Phantom power can be selected via a DIP switch to provide power to condenser microphones Input channels 1 and 2 can take priority over all other microphone...

Страница 10: ...with a 0 5 A constant current until the battery voltage reaches 27 4 VDC The charger then switches over to constant voltage charging also known as float charging Note When using the unit with backup power of 24 V make sure that the unit is always powered ON When the unit is switched OFF the batteries will be drained as this will be regarded as a power source Consequently the unit will revert to 24...

Страница 11: ... Master low tone control for music inputs 14 Zone 1 selection button 15 Zone 2 selection button 16 Air inlet holes 17 Headphone socket 2 4 2 Plena PLE WP2Z3S wall panel The optional Plena PLE WP2Z3S wall panel can be used to remotely control the unit from a maximum of four remote locations The appearance of the wall panel is matched to the Bosch loudspeaker volume controls The zone can be activate...

Страница 12: ... Tel emergency 70V input Euro style pluggable screw terminal connector VOX function This input has highest priority 13 Call station input RJ 45 connector PLE 2CS or PLE 2CS MM chimes are in call station This input has second highest priority 14 Remote control wall panel input RJ 45 connector Wall panel incorporates BGM source selection and zone on off control 15 Telephone emergency 70V input volum...

Страница 13: ...ower 40VA Zone 1 Out Zone 2 Out Line Out Music Only Chime Ducking 0 100V In 1 disc 2 radio 3 aux Insert Out Call Trigger Gnd Telephone Emergency Input Gnd PLE 10M2 EU 2 Channel Mixer 115 230V 50 60Hz S N Design Quality The Netherlands F01U 066 938 8900 192 21001 Chime Flat PTT Mic Flat Vox Mic Phantom Off Speech Off Line Speech Off Line Off Mic Line Mic Line Phantom Off Mic Line Mic Line Phantom O...

Страница 14: ...Bosch Security Systems 2007 10 PLE 2MA120 US PLE 2MA240 US en Plena Mixer Amplifier Installation and User Instructions Description en 12 Intentionally left blank ...

Страница 15: ...ure that it does not exceed the overheating temperature 55 C ambient use the included Bosch mounting brackets LBC 1901 00 remove the 4 feet from the bottom of the unit 3 3 Check settings connections 1 Connect any additional equipment see section 4 1 and 4 2 2 Check the settings see section 4 3 3 4 Connect unit to mains 1 Make sure the voltage selector 115V 230V is correctly set for the country s m...

Страница 16: ...Bosch Security Systems 2007 10 PLE 2MA120 US PLE 2MA240 US en Plena Mixer Amplifier Installation and User Instructions Installation en 14 Intentionally left blank ...

Страница 17: ...ted battery or batteries if connected in series A separate battery charger is therefore not required The charger charges the battery with a 0 5 A constant current until the battery voltage reaches 27 4 VDC The charger then switches over to constant voltage charging also known as float charging This means that a battery can be charged at the same rate it is discharging and thus full capacity batter...

Страница 18: ...gnal all inputs including microphone line 1 input with trigger will be overruled The microphone line 1 input with trigger has a Euro style pluggable screw terminal connector This Euro style pluggable screw terminal connector has a trigger input which can be used in combination with the Euro connector The priority microphone can be connected to the microphone line 1 input with trigger as follows Eu...

Страница 19: ...ending on the setting of the ducking level control at the rear of the unit See section 4 3 The Tel emergency 70V input Call station input and Microphone line input 1 with trigger all have priority over the Microphone line input 2 Therefore any signal received on any one of these inputs will always be heard regardless of the ducking level control setting for Microphone line input 2 Set the DIP swit...

Страница 20: ...easons the volume of the emergency announcement or signal cannot be set to zero The master volume control setting 7 does not influence the volume setting of the emergency announcement or signal 4 1 5 1 Connecting 70 Volt input signal Connect the 70 Volt input signal as shown in figure 4 4 Caution Never connect telephone lines and a 70 V signal to the Euro style connector at the same time Note Tel ...

Страница 21: ...network must always be made via a telephone coupler that provides adequate isolation between the telephone network PBX and the Plena system The telephone coupler must also meet all relevant requirements for this type of communication equipment as imposed by law and or responsible telecommunication organizations in the country of use Never try to make a direct connection between the telephone netwo...

Страница 22: ...ser Instructions Connections and settings en 20 4 1 6 Music source inputs When using a CD player tuner or other auxiliary device for background music connect the line out connectors of the music source to the appropriate line in connectors of the mixer amplifier figure 4 6 Connecting music source inputs ...

Страница 23: ...sic out source for another device For example the music master output can be connected to a telephone coupler so that callers can listen to music when they are put on hold see figure 4 7 To select the dedicated music out source set the master switch for line out or music only 22 to music only Only the music inputs 18 19 and 20 will be audible All other inputs including the Tel emergency 70V input ...

Страница 24: ...should not exceed the rated amplifier output power You can use the Call Only output for 3 wire remote volume control override You can also use this output as an extra zone where announcements can be heard but not music 4 2 5 2 Low impedance loudspeakers Connect low impedance loudspeakers to the 4 Ohm 0 terminals This output can deliver the rated output power into an 4 Ohm load Connect multiple lou...

Страница 25: ...gnal will be mixed with the other mic line signals Microphone 1 will mix with the background music or the other microphones in the selected zones Users can have private conversations during live broadcasts for example with an all call call station such as the PLE 1CS Line Input signal from line Input signal from microphone Depends on set up Speech filter Enhances clarity of speech by cutting off t...

Страница 26: ...ng used in large open areas or when important announcements have to made Telephone emergency 70V volume control Attenuates the emergency announcement or signal Control range from 25 dB to 0 dB For safety reasons the volume of the emergency announcement or signal cannot be fully set to zero Set the volume of the emergency announcement to a higher level when the system is being used in large open ar...

Страница 27: ...e the preferred settings of the unit The red pins can optionally be used to indicate the maximum setting of a knob If these settings have to be changed use a pair of soft tipped pliers to carefully remove the pins If you do not have a pair of soft tipped pliers you can use ordinary pliers instead but first place some plastic tape on the tips of the pliers to prevent damaging the front of the unit ...

Страница 28: ...Bosch Security Systems 2007 10 PLE 2MA120 US PLE 2MA240 US en Plena Mixer Amplifier Installation and User Instructions Connections and settings en 26 Intentionally left blank ...

Страница 29: ...age selector 115V 230V is correctly set for the country s main voltage see figure 5 1 2 Set the power button 1 on the front of the unit to On pushed in see figure 5 2 5 1 2 Switch off Set the power button 1 on the front of the unit to Off popped out see figure 5 2 Caution Potential equipment damage Before applying power always check the voltage selector at the rear of the unit figure 5 1 Voltage s...

Страница 30: ...hone and line inputs boosts warmth in voices without boosting rumble and cuts rumble without loosing warmth in the low frequencies In the high frequencies the tone control boosts sparkle without adding sharpness but when cutting is first cuts harshness and sharpness without reducing clarity Use the Hi high and Lo low tone controls see figure 5 2 numbers 3 and 10 to collectively change the tone of ...

Страница 31: ...ttons 14 and 15 to route the music microphone line mix from the amplifier output to loudspeaker zone 1 and or loudspeaker zone 2 Announcements however are always routed to both zones irrespective of the position of the zone selection buttons 5 5 2 Master volume control Use the master volume control dial 7 to collectively control the sound level of all outputs except the emergency announcement sign...

Страница 32: ...Bosch Security Systems 2007 10 PLE 2MA120 US PLE 2MA240 US en Plena Mixer Amplifier Installation and User Instructions Operation en 30 Intentionally left blank ...

Страница 33: ...10 dB ref rated output Distortion 1 rated output power 1 kHz Low Control Max 12 12 dB frequency is level dependent Hi Control Max 12 12 dB frequency is level dependent Call station input For PLE 2CS MM Wall panel input For PLE WP3S2Z Input 1 Push to talk contact with ducking functionality 5 pin Euro style balanced phantom Input 2 6 VOX with ducking functionality on input 2 5 pin Euro style balance...

Страница 34: ...vity 70V 7 V 70 V adjustable Impedance 10 kohm S N flat at max volume 65 dB VOX threshold 50 mV attack time 150 ms release time 2 s Connector Cinch Nominal level 1 V Impedance 10 kohm Connector 3 pin XLR balanced Nominal level 1 V Impedance 100 ohm Connector Screw floating Max rated PLE 2MA120 US 180 W 120 W Max rated PLE 1906 10 360 W 240 W Connector Euro style pluggable screw terminal floating P...

Страница 35: ......

Страница 36: ...For more information visit www boschsecuritysystems com Bosch Security Systems B V Data subject to change without notice 2007 10 PLE 2MA120 US PLE 2MA240 US en ...

Отзывы: