Bosch Plena PLE-10M2-EU Скачать руководство пользователя страница 2

requires boosted low frequencies, the microphone
voices will still be clear – a truly unique feature in its
class.
The tone controls also have the following unique
features:

• The mixer features separate tone controls for mic/line

inputs and music inputs so the microphone voice can
be specifically optimized for excellent speech or
singing

• The tone controls for music enable the most suitable

music reproduction

In addition, the tone controls are not standard bass
and treble controls; our experience has enabled us to
develop a tone control that can be used as a
traditional tone control with high and low control, but
with a powerful contour that addresses the problems
that are found in real situations.

 

The tone control for the microphone and line inputs:

• boosts warmth in voices without boosting rumble,

and cuts rumble without losing warmth in the low
frequencies

• boosts sparkle without adding sharpness in the high

frequencies when boosting, and reduces harshness
and sharpness without reducing clarity when cutting

 

The tone control for the music inputs:

• boosts deep bass first without making the sound

hollow or boomy, and cuts rumble without losing
warmth in the low frequencies

• boosts sparkle without adding sharpness in the high

frequencies, with slightly different frequencies to suit
music reproduction

Integration

A telephone / 100 V emergency input with VOX
activation is provided for easy integration with another
PA system or a telephone paging system. It has its own
preset volume control and overrides all other inputs,
including call station and inputs 1 and 2.

Zones

The mixer has two zone outputs. The music can be
switched on and off in the zones via the front panel
and optional wall panel. Announcements from the
PLE-2CS two-zone call station can be routed to zone 1
or zone 2, or both. Announcements from the tel/100 V
input or inputs 1 & 2 are routed to both zones. Input 1
can be used for a PLE-1CS all-call call station or any
other microphone or call station with a PTT contact.
The unit also has a line output to connect the pre-
amplifier output before zone selection, making it
possible to create a third zone. This output can be
switched to music only, for example, so that music on
hold can be provided for the telephone system. Loop-
through input and output connections enable external
sound processing equipment (e.g. an equalizer or
Plena feedback suppressor) while maintaining a
balanced connection to the amplifiers.

Output status

An LED VU meter monitors the master output. A
headphone socket, below the VU meter, provides the
mixer output before zone selection so you can listen to
the output before the signal is sent to the zone.

 
Controls and indicators

Front

• On/off switch
• Power on LED
• LED VU meter for master output (LEDs for -18, -12 -6,

-3, 0 dB)

• Master volume knob
• Six volume knobs for microphone inputs
• Knob for treble level
• Knob for bass level
• Headphone socket
• Two zone selector buttons
• Background music button

Back

• Dip switches
• Chime level
• Ducking level
• Tel/100 V volume control

Interconnections

See Technical Specifications.

Certifications and approvals

Safety

acc. to EN 60065

EMC emission

acc. to EN 55103-1

EMC immunity

acc. to EN 55103-2

Region

Certification

Europe

CE

Installation/configuration notes

Rear view

Parts included

Quantity

Components

1

PLE-10M2-EU Plena Mixer

1

Power cord

1

Manual

2 | PLE‑10M2‑EU Plena Mixer

Содержание Plena PLE-10M2-EU

Страница 1: ...tched automatically if a signal is fed to the input i e if someone speaks into the microphone VOX activation A 2 tone chime can be configured to precede an announcement Input 2 also has a VOX possibility When one or both inputs are configured for priority the attenuation reduction of the cinch input can be set between 2 dB little attenuation and dB mute This provides a talk over or voice over func...

Страница 2: ... Zones The mixer has two zone outputs The music can be switched on and off in the zones via the front panel and optional wall panel Announcements from the PLE 2CS two zone call station can be routed to zone 1 or zone 2 or both Announcements from the tel 100 V input or inputs 1 2 are routed to both zones Input 1 can be used for a PLE 1CS all call call station or any other microphone or call station...

Страница 3: ...ume muted 75 dB CMRR mic 40 dB 50 Hz to 20 kHz Speech filter 3 dB 315 Hz high pass 6 dB oct Phantom power supply 16 V via 1 2 kohm mic Speech filter 3 dB 315 Hz high pass 6 dB oct VOX input 1 2 attack time 150 ms release time 2 s Music inputs 3 x Connector Cinch stereo converted to mono Sensitivity 300 mV Impedance 22 kohm S N flat at max volume 70 dB S N flat at min volume muted 75 dB Headroom 25...

Страница 4: ... securitysystems bosch com www boschsecurity com Robert Bosch SEA Pte Ltd Security Systems 11 Bishan Street 21 Singapore 573943 Phone 65 6571 2808 Fax 65 6571 2699 apr securitysystems bosch com www boschsecurity asia Bosch Shanghai Security Systems Ltd 201 Building No 333 Fuquan Road North IBP Changning District Shanghai 200335 China Phone 86 21 22181111 Fax 86 21 22182398 www boschsecurity com cn...