background image

For safety and economic gas usage you should always 
use the correct pan on the correct burner.Flames should 
not protrude beyond the base of the pan. You will save 
energy, time and money by always placing the correct 

The chart below gives the correct pan usage for each burner

User Instructions  

For safety and economic gas usage you should always 

use the correct pan on the correct burner.Flames should 
not protrude beyond the base of the pan. You will save 
energy, time and money by always placing the correct 
pan size on the correct gas ring. See fig. 15.

The chart below gives the correct pan usage for each burner

Burner

Recomended 
pan diameter

 Minimum 
pan diameter

Small burner

Medium 
burner

220 mm.

Wok burners

220-260 mm.

Large burner

User Instructions  

Use “High flame” setting to bring the pan to the boil, then 
adjust the flame between “High flame” and “Low flame” 
t o   m a i n t a i n   t h e   r e q u i r e d   p a n   t e m p e r a t u r e .
Important:
The use of a cooktop leads to the production of heat and 
moisture in the kitchen .For this reason make sure that 
the room is properly ventilated.Keep natural ventilation 

mechanical ventilation device(e.g. a range hood or 
overhead exhaust fan). An orangy flame is normal and 
simply indicates the presence of salt in the atmosphere 
(from cooking). If the flame has yellow patches, this is 
not a fault (of any kind).

Boiling burners

such as windows, open or provide a 

openings,

pan size on the correct gas ring. See fig. 

.

14

14

>

_

120-140 mm.

120 mm.

140-200 mm.

140 mm.

220 mm.

>

_

Big wok burners

220 mm.

an extra wok trivet. This trivet must be used when using

concave receptacles such as woks, etc.

non-use or misuse of this additional pan support.

Depending on the model, the hotplate is supplied with

than 26 cm diameter, griddle plates and all kinds of

an extra coffee support. This support is for use only

The manufacturer cannot be held responsible for the

with the small burner when supporting receptacles

with a diameter of less than 10 cm.

the wok burner for receptacles with diameters of more 

The manufacturer cannot be held responsible for the

Depending on the model, the hotplate is supplied with

non-use or misuse of these additional pan supports.

Wok trivet

Coffee support

15

3

3

 

                  

4.Once the hob is fitted you should turn the clips and

4

tighten the screw as shown in Fig. 4.

that the hob is resting on its entire perimeter.

3.

Place the hotplate on top of the bench cut-out and 

press down firmly on all edges at the same time to ensure 

8

Содержание PCL985FAU

Страница 1: ... Straße 34 81739 München Robert Bosch Hausgeräte GmbH Internet http www bosch hausgeraete de This cooktop is for use with Natural Gas and Universal LPG Cod 9000198453 C PCL985FAU PCN985FAU PCR915B90A PCT915B90A ...

Страница 2: ......

Страница 3: ...ransportation All the material used for packing is considered essential for this purpose and is also completely recyclable You too can contribut towards protecting the environment by disposing of this material at your nearest recyclable refuse collection point Do not dispose of used cooking oil down the kitchen sink Oil may seriously damage the environment Dispose of it in a closed container at yo...

Страница 4: ... 19 19 18 17 17 A B C E C D L N A Switch B Blue wire C Brown wire D Terminal E Ignition module Wiring diagram Robert Bosch Hausgeräte GmbH CIF A 28 893550 Gas type Test point pressure kPa 1 0 2 75 Injectors sizes mm 0 67 HGC MJ Electrical compliance AGA approval number Preinstalled NG In compliance with AS 3100 Robert Bosch Hausgeräte GmbH CIF A 28 893550 Gas type NG 1 0 2 75 HGC MJ Electrical com...

Страница 5: ...d the burner needs to carefully The burner covers are not Dry the burner covers Make sure that the burner covers are correctly positioned correctly positioned The burners may not be are dirty totally dry Dry the burners more The burner components have thoroughly be particularly careful with single piece The gas ports on the burners burners at all Possible leak on the gas bottle coupling 19 Safety ...

Страница 6: ...th the feet on the metal grids when cleaning them if they are detached the grid may scratch the glass next time it is used DON Ts DOs Clean the surface of the heating elements once they have cooled down each time they are used Even small amounts of dirt burn when it is switched on again The burners and pans su pport must be cleaned re gulary to keep them clean This is done by submer ging them in s...

Страница 7: ...Always use suitably sized receptacles on each bur ner This helps avoid ex cessive gas consumption and prevents receptacles from getting tarnished Do not use two burners or heat sources for a single Do not use baking trays earthenware dishes etc at full heat for a long time Only use one recipient per burner Use the extra saucepans and casseroles cles burners crease energy consumption on the pans su...

Страница 8: ...g on the model keeps the entire work surface watertight and prevents spilage from leaking into cupboards underneath Slightly do not under any circumstance remove them The seal losen the retaining screws of the clamps positioned at the bottom of the cooktop b If the clamps and the selfadhesive seal have not the gas burner covers from your cooking hob and turn it upside down Now fit the selfadhesive...

Страница 9: ...g a range hood or overhead exhaust fan An orangy flame is normal and simply indicates the presence of salt in the atmosphere from cooking If the flame has yellow patches this is not a fault of any kind Boiling burners such as windows open or provide a openings pan size on the correct gas ring See fig 14 14 _ 120 140 mm 120 mm 140 200 mm 140 mm 220 mm _ Big wok burners 220 mm an extra wok trivet Th...

Страница 10: ... leakage on connections performed by the installer or if the L tube is moved For position of the inlet connection refer Fig 1 1a or twisted connections connection as per Fig 5 and Fig 6 R Fit regulator N G or a test point Universal LPG directly to the 5 6 Natural gas connection Pressure test point R 1 2 R 1 2 Pressure test point Gasket Gasket Universal LPG connection This appliance is connected to...

Страница 11: ...sure that the hose does WARNING Ensure that the hose assembly is restrained from accidental contact with the flue outlet of an under bench oven and water DO NOT use a naked flame for detecting leaks Turn gas taps to low flame position and observe stability of the flame for each burner individually and all together Adhere the duplicate data plate to an accessible location near the hotplate the user...

Страница 12: ... 0 67 0 85 Hourly Gas Comsumption MJ 4 0 1 55 Big wok Center Burner outer 0 68 13 0 1 65 0 93 Big wok Center inner 0 43 wok Right and left front Universal LPG 11 5 15 1 10 14 6 6 5 0 85 included in above included in above 3 25 6 25 9 5 10 8 11 5 To adjust the minimum flame for N G replace the control knob onto the spindle light the gas and turn the adjustment screw anti clockwise to estabilish a m...