• If the information in this manual is not followed ex-

actly, a fire or explosion may result causing prop-

erty damage, personal injury or death.

• Do not store articles on or against this appliance.
• Do not store flammable materials near this appli-

ance.

• Do not spray aerosols in the vicinity of this appli-

ance while it is in operation.

• Do not try to light the appliance.
• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a neighbour’s

phone. Follow the gas supplier’s instructions.

• If you cannot reach your gas supplier, call the fire

department.

• Installation and service must be performed by an

authorised person.

1. Do not allow the flame to extend beyond the edge

of the cooking utensil. This instruction is based on

safety considerations.

2. Do not forget that the unit becomes hot when in

use. Common sense is important. Just because

the flame is out, does not mean parts cannot still

be hot.

3. This appliance shall not be used for space heat-

ing. This instruction is based on safety considera-

tions.

4. Be sure to disconnect the electrical supply before

disassembly of the appliance.

5. Keep the appliance area clear and free from com-

bustible materials, gasoline and other flammable

vapours and liquids.

6. This appliance  must be installed in a position

with the proper level of ventilation. Do not ob-

struct the flow of combustion and ventilation air.

7. Cabinets installed above the gas cooktop must

have a minimum clearance of 650 mm (24”).

8. The gas pressure regulator supplied with the ap-

pliance must be installed in line with the gas pipe.

(N.G. only)

13

Do’s

• Once the appliance is cold, clean it with a sponge

and soapy water. Remove any spills immediately.

This will avoid unnecessary effort later.

• Allow burners and trivets to cool down before clean-

ing them.

• The burners and trivets must be cleaned regularly to

keep them in good condition. This is done by sub-

merging them in soapy water and scrubbing them

with a non-metal brush to keep the ports and slots

free from obstructions so they give a perfect flame.

Dry the burner caps and trivets whenever wet or

damp.

• After cleaning and drying ensure that the burner

heads and caps are replaced correctly on the burner

body. Refer Fig. 6.

• The high temperatures generated by using the wok

burner may cause the stainless steel hob of your

hotplate to become discoloured over time. THIS IS

NORMAL. Clean the hob with a product suitable

for cleaning stainless steel.

• The trivets on your hob are fitted with rubber feet.

Be careful when cleaning as they may be dislodged

during cleaning, leaving the stainless steel hob un-

protected and subject to surface scratching .

Don’t

• Never use abrasive products, sharp objects, steel

scouring pads, knives, etc., to remove stubborn food

remains from the hob surface, trivets and burners.

• Do not allow acidic products such as vinegar, lemon

juice, etc., to come into contact with the hob.

Cleaning

For your safety

What to do if you

smell gas

Warnings

Safety considerations

Содержание PCL 785 FAU

Страница 1: ...ATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS This cooktop is for use with Natural and Propane gases Leave these instructions with the owner MAKERS WARRANTY BOSCH Booklet designed and produced by DESIGN MAXIM 03 0853 7491 BOSCH Part No W1531 Version Bosch A ...

Страница 2: ...lbourne 1300 30 70 37 head office Sales Customer and Technical Service New Zealand 0800 4BOSCH 0800 426 724 Sales and Customer Service Robert Bosch Australia Pty Ltd Incorporated in Victoria ABN 48 004 315 628 Victoria Cnr Centre McNaughton Roads Clayton 3168 Phone 03 9541 5555 Fax 03 9541 5595 New Zealand 14 16 Constellation Drive Mairangi Bay Auckland 1310 Phone 09 478 6158 Fax 09 478 2914 Servi...

Страница 3: ...d replace if faulty The automatic circuit Check to see if the circuit breaker or mains breaker or a differential has differential has been been triggered in the mains triggered supply box If the electronic ignition There may be food or The gap between the spark system does not work cleaning product plug and the burner needs to particles between the be cleaned carefullly spark plugs and the burners...

Страница 4: ...ation air 7 Cabinets installed above the gas cooktop must have a minimum clearance of 650 mm 24 8 The gas pressure regulator supplied with the ap pliance must be installed in line with the gas pipe N G only 13 Do s Once the appliance is cold clean it with a sponge and soapy water Remove any spills immediately This will avoid unnecessary effort later Allow burners and trivets to cool down before cl...

Страница 5: ... properly ventilated Keep natural ven tilation openings such as windows open or provide a mechanical ventilation device e g a range hood or overhead exhaust fan For safety and economic gas usage you should al ways use the correct pan on the correct burner Flames should not protrude beyond the base of the pan You will save energy time and money by always placing the correct pan size on the correct ...

Страница 6: ...ss control knob and turn anti clockwise to High flame position Hold the knob down for a few sec onds until the flame ignites Keep control knob de pressed for a few seconds to activate the flame failure device If ignition fails depress knob again and wait for ignition Turn anti clockwise to set the flame to the desired intensity All burners are fitted with a flame failure device which shuts off the...

Страница 7: ...ave a space at least 100mm between any drawer partition or oven that is installed underneath the cooktop Minimum thickness of benchtop is 15mm See Fig 2 Installation procedure 1 For cutout dimensions and clearances refer Fig 1 2 The hotplate is factory fitted with sealing tape around the lower edge of the hob and two pres sure clamps either side The seal keeps the entire work surface watertight an...

Страница 8: ...and Fig 5 Direction of gas flow is indicated on the rear of the regulator For position of the inlet connection refer Fig 1 Natural gas connection Propane gas connection Connection Installation continued 9 It should be expressly noted that we cannot accept any liability for direct or indirect damage caused by wrong connection or improper installation When being repaired the appliance must always be...

Отзывы: