background image

Carl-Wery-Straße 34
81739 München

Robert Bosch 

Hausgeräte GmbH

www.bosch-home.com

This cooktop is for use with Natural Gas and Universal LPG

Cod. 

9000617265 A

PCI815B91A

Содержание PCC615B90A

Страница 1: ...Carl Wery Straße 34 81739 München Robert Bosch Hausgeräte GmbH www bosch home com This cooktop is for use with Natural Gas and Universal LPG Cod 9000617265 A PCI815B91A ...

Страница 2: ...rs 11 Changing the nozzles of the burners on the cooktop 12 Adjustment of the taps 13 Operating instructions 15 Burner locations 15 The gas burners Operation 15 Switching on automatically 15 Safety system 16 Switching off a burner 16 Power levels 16 Warnings 16 Suitable pans 17 Accessories 17 Additional wok pan support 17 Additional coffee maker support 18 Cooking recommendation 18 Precautions for...

Страница 3: ...s which are strictly necessary to guarantee efficient protection during transport These materials are 100 recyclable thus reducing the environmental impact You can also contribute to caring for the environment by following the advice below dispose of the packaging in the appropriate recycling bin before you get rid of an old appliance make sure you disable it Contact your local authority to find o...

Страница 4: ...dge of the cooking utensil This instruction is based on safety considerations Do not forget that the unit becomes hot when in use Common sense is important Just because the flame is out does not mean parts cannot still be hot This appliance shall not be used for space heating This instruction is based on safety considerations Be sure to disconnect the electrical supply before disassembly of the ap...

Страница 5: ... the fault Do not use unstable or uneven based receptacles on cooking plates or burners They may accidentally tip over If a gas supply knob valve jams do not force it Call your official Service Centre immediately for them to repair or replace it The illustrations used in this booklet are only intended as a guide Grids become very hot during use When operating the appliance control knobs take care ...

Страница 6: ... Gas Installations Ø S A A Wiring Code Ø Local Electrical Regulations Ø Any other statutory regulations Preparing to install Refer to AS NZS 5601 1 for piping size details These built in cooktops are intended to be inserted in a benchtop cutout Only an officially authorised technician should connect the appliance Before you begin turn off the gas and electricity supply Installation dimensions are ...

Страница 7: ...n Any adjoining wall surface situated within 200 mm from the edge of any hob burner must be a suitable non combustible material for a height of 150 mm for the entire length of the hob Any combustible construction above the hotplate must be at least 650 mm above the top of the burner and no construction shall be within 450 mm above the top of the burner A minimum depth of 50 mm from the top of the ...

Страница 8: ...ll turn freely it is not necessary to completely undo them Insert and centre the cooktop Press the sides of the cooktop until it is supported around its entire perimeter Turn the clips and tighten them fully Fig 3 Fig 3 Connection Electrical Fig 4 An electrical 10 amp socket needs to be within 1 m of the hotplate to allow electrical connection The socket must remain accessible after installation o...

Страница 9: ...R 1 2 connection as per Fig 5 and Fig 6 Direction of gas flow is indicated on the rear of the regulator For position of the inlet connection refer Fig 1 Use pipe compound or thread sealant properly theaded pipes and careful assembly procedure so that there is no cross threading etc which might cause damage or leakage Make sure that all connections peformed are free of leakage The manufacturer does...

Страница 10: ...lves burners and ignition Turn gas taps to low flame position and observe stability of the flame for each burner individually and all together Adhere the duplicate data plate to an accessible location near the hotplate When satisfied with the hotplate please instruct the user on the correct method of operation In case the appliance fails to operate correctly after all checks have been carried out ...

Страница 11: ...version the cooktop must be disconnected from the electricity and gas valves must be turned to the OFF position Changing the nozzles of the burners on the cooktop Remove the pan supports burner covers and diffusers Fig 7 Fig 7 Change the nozzles using the spanner provided by our Service Centre code 340847 for double and triple flame burners code 340808 taking special care to ensure that the nozzle...

Страница 12: ...i clockwise to estabilish a minimum stable flame position The flame should remain alight and not burn back to the injector when the valve is turned quickcly from Full On to the Minimum flame position and back a few times To adjust the minimum flame position for ULPG the screw must be fully tightened down clockwise If the by pass screw cannot be accessed disassemble the grease splash tray which is ...

Страница 13: ... to removal It is important that all the seals are refitted to form a seal These devices are essential for the correct operation of the appliance as they prevent liquids and dirt from entering the appliance Refit the control knobs Never remove the tap spindle In the event of a malfunction change the whole tap Fig 11 Fig 11 Warning After finishing the sticker indicating the new type of gas must be ...

Страница 14: ...ration There are indications to show which burner each control knob operates Fig 12 Fig 12 It is essential to ensure that all the burner parts and pan supports are correctly installed for the appliance to work correctly Fig 13 14 Fig 13 Fig 14 Switching on automatically If your cooktop can be switched on automatically ignition sparkers 1 Press the chosen burner control knob and turn it anticlockwi...

Страница 15: ... Turn the corresponding control knob clockwise to the 0 setting Power levels The progressive control knobs can be used to control the power needed from minimum to maximum power Setting Control off Large flame Maximum capacity or aperture and electricity on Economy flame Minimum capacity or aperture Warnings It is normal to hear a slight whistling noise while the burner is operating When it is firs...

Страница 16: ...d Keep natural ventilation openings such as windows open or provide a mechanical ventilation device e g a range hood or overhead exhaust fan An orangy flame is normal and simply indicates the presence of salt in the atmosphere from cooking If the flame has yellow patches this is not a fault of any kind The chart below gives the correct pan usage for each burner Burner Minimum pan diameter Maximum ...

Страница 17: ...agout Steaming and vegetables Semi rapid burner Steaming potatoes fresh vegetables stews pasta Reheating keeping things hot and making tasty casseroles Auxiliary burner Casseroles rice pudding and caramels Defrosting and slow cooking vegetables fruits and frozen products Melting butter chocolate and jelly Do not place anything eg flame tamer asbestos mat between pan and pan support as serious dama...

Страница 18: ...ook without using a lid and make sure the lid is properly fitted to avoid wasting energy Always place the pan right over the burner not to one side Otherwise it could tip over Do not place large pans on the burners near the control knobs These may be damaged by the very high temperatures Place the pans on the pan supports never directly on the burner Pans should be placed on the cooktop carefully ...

Страница 19: ...ge the enamel After cleaning and drying the burners make sure the burner covers are correctly placed on the diffuser Unsuitable products Do not use steam cleaners This could damage the hob If your hob is fitted with a glass or aluminium panel never use a knife scraper or similar to clean the point where it joins the metal Maintenance Always clean off any liquid as soon as it is spilt you will save...

Страница 20: ...ntact the electrical installer The burner flame is not uniform The burner components are not correctly positioned The grooves on the burner are dirty Ensure the components are correctly positioned Clean the grooves on the diffuser The flow of gas does not appear normal or no gas comes out The gas supply is blocked via intermediary valves If the gas is supplied from a gas cylinder check that this i...

Страница 21: ...led NG Injectors marks www bosch home com CIF A 28 893550 ROBERT BOSCH HAUSGERÄTE GMBH NG 1 0 MADE IN SPAIN Distributed by BSH Home Appliances Pty Ltd GMK 10047 E Nr PCI815B91A LH RH Test point pressure kPa CR CF 182 100 155 ULPG 85 118 90 67 2 75 50 36 90 33 00 In compliance with AS NZS 3100 and AS 4551 2008 ...

Отзывы: