Installation Instructions
Models: NEM73, NEM93
Table of Contents
NOTE:
The blocked letters, such as
A
, shown below, refer to illustrations on
Pages
2
&
4
. Match these to the related text pages.
Overall Dimensions
A
............................................................................................... 2
Power Supply
B
.......................................................................................................... 2
Cabinet Preparation and Clearances
C
............................................................. 2, 3
Junction Box Location
D
........................................................................................... 2
Countertop Cutout Dimensions
E
........................................................................ 2
Installing the Cooktop
F
........................................................................................ 3-4
Secure Cooktop to Countertop
G
..................................................................... 3-4
Solid Surface Countertop Installations
H
and
I
............................................... 4-5
Electrical Connection ................................................................................................ 5
OVERALL DIMENSIONS
A
See Illustration
A
, Page
2
. These dimensions are overall.
POWER SUPPLY
B
ELECTRICAL POWER CONNECTION
FOR COOKTOP
Power Supply is dual rated: 240 Volts or 208 Volts, 3
wire, 60 Hz, with the following circuit breaker
requirements: Model NEM73 at 30 Amps; Model
NEM93 at 40 Amps
Connect only to a 3-wire 120/240 or 120/208 volt ac
system. The neutral is not required for the operation
of this appliance but an independent ground is required.
Install a junction box (not supplied), below the counter
top within 3 feet of flexible conduit (supplied) located
at the left rear corner of the cooktop rough-in box.
IMPORTANT:
Save these instructions for Local Electrical Inspector’s use.
INSTALLER:
Please leave these Installation Instructions with this unit for the owner.
OWNER:
Please retain these instructions for future reference.
READ AND SAVE THESE INSTRUCTIONS
JUNCTION BOX LOCATION
D
Plan the installation of the unit so that the location of
the junction box is within 3 feet of the left rear of the
cooktop bottom.
It must be accessible from the
front of the cabinet.
PAGE 1