40
en | Advanced Mode
IP Camera 200 Series
AR18-09-B003 | v1.1 | 2010.05
Installation and Operation Manual
Bosch Security Systems
–
MODEM
QVGA resolution for analog modem connections at 22 kbps
maximum
–
GSM
QVGA resolution for GSM connections
Profile Configuration
Profiles can be configured for use with the H.264 settings of
encoder streams. Select a profile by clicking the appropriate
tab. Change the name of a profile and individual parameter
values within a profile.
Profiles are rather complex. They include a number of
parameters that interact with one another, so it is generally
best to use the default profiles. Only change a profile if
completely familiar with all the configuration options.
The parameters as a group constitute a profile and are
dependent on one another. If a setting outside the permitted
range for a parameter is entered, the nearest valid value is
substituted when the settings are saved.
Profile name
Enter a new name for the profile here.
Target data rate
To optimize utilization of the bandwidth in the network, limit
the data rate for the camera. The target data rate should be set
according to the desired picture quality for typical scenes with
no excessive motion.
For complex images or frequent changes of image content due
to frequent movements, this limit can temporarily be exceeded
up to the value entered in the
Maximum data rate
field.
Maximum data rate
This maximum data rate is not exceeded under any
circumstances. Depending on the video quality settings for the
I-frames and P-frames, this can result in individual images being
skipped.
The value entered here must be at least 10% higher than the
value entered in the
Target data rate
field. If the value entered
Содержание NBC-255-P
Страница 1: ...IP Camera 200 Series NBC 255 P en Installation and Operation Manual ...
Страница 2: ......
Страница 93: ......
Страница 94: ...Bosch Security Systems www boschsecurity com Bosch Security Systems 2010 ...